Microchip Technology ICD 3 In-Circuit Debugger DV164035 DV164035 User Manual

Product codes
DV164035
Page of 108
General Setup
© 2008 Microchip Technology Inc.
DS51766A-page 27
4.6
SETTING CONFIGURATION BITS
Although device Configuration bits may be set in code, they also may be set in the 
MPLAB IDE Configuration window. Select Configure>Configuration Bits. By clicking on 
the text in the “Settings” column, these can be changed.
Some Configuration bits of interest are:
• Watchdog Timer Enable – On most devices, the Watchdog Timer is enabled 
initially. It is usually a good idea to disable this bit.
• Comm Channel Select – For some devices, you will need to select the commun-
cations channel for the device, e.g., PGC1/EMUC1 and PGD1/EMUD1. Make 
sure the pins selected here are the same ones physically connected to the device.
• Oscillator – Select the configuration setting that matches the target oscillator.
4.7
SETTING THE DEBUGGER AS THE DEBUGGER OR PROGRAMMER
Select Debugger>Select Tool>MPLAB ICD 3 to choose the MPLAB ICD 3 in-circuit 
debugger as the debug tool. The Debugger menu and MPLAB IDE toolbar will change 
to display debug options once the tool is selected. Also, the Output window will open 
and messages concerning MPLAB ICD 3 status and communications will be displayed 
on the MPLAB ICD 3 tab. For more information, see Section 9.2 “Debugging 
Functions”
 and Section 9.3 “Debugging Dialogs/Windows”.
Select Programmer>Select Programmer>MPLAB ICD 3 to choose the MPLAB ICD 3 
in-circuit debugger as the programmer tool. The Programmer menu and MPLAB IDE 
toolbar will change to display programmer options once the tool is selected. Also, the 
Output window will open and messages concerning ICE status and communications 
will be displayed on the MPLAB ICD 3 tab. For more information, see 
Section 9.4 “Programming Functions”.
Select Debugger>Settings or Programmer>Settings to open the Settings dialog 
(Section 9.5 “Settings Dialog”) and set up options as needed.
If errors occurs, see:
4.8
DEBUGGER/PROGRAMMER LIMITATIONS
For a complete list of debugger limitations for your device, please see the MPLAB 
ICD 3 on-line help file in MPLAB IDE by selecting Help>Topics>MPLAB ICD 3 and click  