8.5.3.7.2
ICSP Settings
These options will be available only if the selected device supports ICSP.
1. ICSP Power Source – MPLAB PM3 displays the current ICSP power source and 
provides two options:
• Power from MPLAB PM3 – programming the device will be powered 
through MPLAB PM3.
• Target has own supply – programming the device will be powered from 
the target’s own power supply.
2. ICSP Programming Mode – MPLAB PM3 displays the current ICSP program 
mode voltage criteria and provides two options:
• MCLR High Voltage – utilizes MCLR high voltage for programming the 
device.
• PGM Pin (LVP) – utilizes the low voltage programming pin for program-
ming the device.
8.5.3.7.3
Adjust Voltages
This option enables you to adjust the V
DD
 nominal, V
DD
 A
PP
 and 
V
PP
 for a Flash device 
and V
DD
 Max, V
DD
 Min, V
DD
 Nominal and V
PP
 for an EEPROM device.
Each option displays the current setting and enables you to select “Up” or “Down”. 
Each time you press <Enter> the voltage setting is adjusted up or down by 0.125.
8.5.3.7.4
Reset Voltages
To reset the voltages, select All Functions>Settings>Reset Voltages and press 
<Enter>. This command resets the voltages to the default voltages.
8.5.3.7.5
Reset Statistics Count
To reset all the program statistics, select All Functions>Settings>Reset Statistics Count 
and press <Enter>. This command will reset the counters to zero.
8.5.3.7.6
Safe Mode
Safe mode was designed to prevent operational errors during production. When in Safe 
mode, the only functions that are allowed are Program and Verify. If any other buttons 
are pressed, a message is displayed stating that the system is in Safe mode and the 
operation is not allowed. Requesting other functions in MPLAB IDE when MPLAB PM3 
is connected to the PC will deactivate Safe mode.
To enter Safe mode, select All Functions>Settings>Safe Mode and press <Enter>. In 
Safe mode, only Program and Verify options on the Command menu are available. 
After Safe mode is implemented, you will be sent to the Command menu.