Texas Instruments Evaluation Module for BQ25060 1A, Single-Input, Single Cell Li-Ion Battery Charger with 50mA LDO BQ250 BQ25060EVM Data Sheet
Product codes
BQ25060EVM
Procedure
www.ti.com
Figure 3. Battery Load Circuit – Replacement for a Single Cell Li-Ion Battery
→
BAT+ to BAT– Voltage
Tracks P/S Input Voltage Minus 1 Diode Drop.
4
Procedure
4.1
Charger Operation with Minimum System Voltage Mode
4.1.1
Turn on PS#1, preset to 5.1 Vdc
Measure
→
V(J4(VLDO)) = 4.9 ±100 mV
4.1.2
For -001: Trim R7, and set TS pin voltage to 0.5 V ± 50 mV. In the software window, click on
enable.
enable.
For -002: Trim R7 and set TS pin voltage to 1 V ±50 mV.
For -001 and -002: Turn on PS#2 set to 2.3 V ±50 mV.
For -001 and -002: Turn on PS#2 set to 2.3 V ±50 mV.
Observe
→
D1(/CHG) on – This is precharge mode and OUT is held at its minimum system
voltage while the adapter is present and the battery below this minimum voltage. This
allows system power-up with a discharged battery.
voltage while the adapter is present and the battery below this minimum voltage. This
allows system power-up with a discharged battery.
Measure
→
Iin = 180 mA ±30 mA
Measure
→
V(J2(OUT)) = 3.5 V ±200 mV
4.1.3
Increase PS#2 to ~3.3 Vdc to raise VBAT to 3 V ±50 mV
Observe
→
D1(/CHG) on –This is fast-charge constant current mode and OUT is held at its
minimum system voltage while the adapter is present and the battery below this
minimum voltage. This allows system power-up with a discharged battery.
minimum system voltage while the adapter is present and the battery below this
minimum voltage. This allows system power-up with a discharged battery.
For -001 Measure
→
Iin = 285 mA ±50 mA
For -002 Measure
→
Iin = 467 mA ±50 mA
Measure
→
V(J2(OUT)) = 3.5 V ±200 mV.
4.1.4
Increase PS#2 to ~4.1Vdc to raise VBAT to 3.8 V ±50 mV.
Observe
→
D1(/CHG) on – This is fast-charge constant current mode and the battery is
above the minimum OUT voltage (with adapter present) so that the external BAT
FET is enabled, and Vout and Vbat track.
above the minimum OUT voltage (with adapter present) so that the external BAT
FET is enabled, and Vout and Vbat track.
For -001 Measure
→
Iin = 285 mA ±50 mA
For -002 Measure
→
Iin = 467 mA ±50 mA
Measure
→
V(J2(OUT)) = 3.8 V ±200 mV
6
bq25050/bq25060EVM
SLUU438 – July 2010
Copyright © 2010, Texas Instruments Incorporated