Texas Instruments TAS5514B-Q1 DKD Evaluation Module TAS5514BQ1DKDEVM TAS5514BQ1DKDEVM Data Sheet

Product codes
TAS5514BQ1DKDEVM
Page of 14
Ch. 4
Ch. 3
Ch. 2
Ch. 1
Power
EVM Description
See
for more details on the 10-pin connector on the EVM,
for more details about the
speaker cables, and
for the power and speaker-cables connections to the EVM.
Figure 3. Wiring Harness for Power and Speaker Connections
Figure 4. Power and Speaker Connections to the EVM
NOTE:
Do not connect any of the speaker outputs to ground. The TAS5514B has full bridged
outputs; connecting to ground triggers a fault.
The outputs can be paralleled by connecting the plus (+) of one channel to the plus (+) of the other
channel. The minus (–) connection of one channel and the minus (–) connection of the other channel must
be connected also. See the data sheet for more details on parallel outputs (PBTL).
2.3
Controls
2.3.1
Standby
The standby switch is located on the front panel. Having the toggle in the Standby ON position forces the
TAS5514B into the standby mode. This is the same as a power-on reset (POR). POR shuts down the
device.
Setting the switch to the Standby OFF position puts the device in the EVM into the power up mode. The
amplifier will perform load diagnostics and then will place the amplifier outputs into play mode. Please
note, that any channel that has a shorted load, short to ground, or a short to power will not be placed into
play mode.
6
TAS5514B Evaluation Module (EVM) User's Guide
SLOU345 – June 2012
Copyright © 2012, Texas Instruments Incorporated