Texas Instruments TLV320DAC3203 Evaluation Module TLV320DAC3203EVM-K TLV320DAC3203EVM-K Data Sheet

Product codes
TLV320DAC3203EVM-K
Page of 44
EVM Description and Basics
2.2
Default Configuration and Connections
2.2.1
USB-MODEVM
provides a list of the SW2 settings on the USB-MODEVM. For use with the
TLV320DAC3203EVM, SW-2 positions 1, 3, 4, 5, 6, and 7 must be set to ON, whereas SW-2.2 and SW-
2.8 must be set to OFF. If the TLV320DAC3203EVM is used with an external audio interface, SW2.4 and
SW2.5 also must be set to OFF and such interface must be connected as explained in
Table 1. USB-MODEVM SW2 Settings
SW-2 Switch Number
Label
Switch Description
1
A0
USB-MODEVM EEPROM I
2
C Address A0
ON: A0 = 0
OFF: A0 = 1
2
A1
USB-MODEVM EEPROM I
2
C Address A1
ON: A1 = 0
OFF: A1 = 1
3
A2
USB-MODEVM EEPROM I
2
C Address A2
ON: A2 = 0
OFF: A2 = 1
4
USB I
2
S
I
2
S Bus Source Selection
ON: I
2
S Bus connects to TAS1020
OFF: I
2
S Bus connects to USB-MODEVM J14
5
USB MCK
I
2
S Bus MCLK Source Selection
ON: MCLK connects to TAS1020
OFF: MCLK connects to USB-MODEVM J14
6
USB SPI
SPI Bus Source Selection
ON: SPI Bus connects to TAS1020
OFF: SPI Bus connects to USB-MODEVM J15
7
USB RST
RST Source Selection
ON: EVM Reset Signal comes from TAS1020
OFF: EVM Reset Signal comes from USB-MODEVM J15
8
EXT MCK
External MCLK Selection
ON: MCLK Signal is provided from USB-MODEVM J10
OFF: MCLK Signal comes from either selection of SW2-5
5
SLAU441 – April 2012
TLV320DAC3203EVM-K
Copyright © 2012, Texas Instruments Incorporated