REGISTER 19-1:
AD1CON1: A/D CONTROL REGISTER 1  
R/W-0
U-0
R/W-0
U-0
U-0
U-0
R/W-0
R/W-0
ADON
ADSIDL
FORM1
FORM0
bit 15
bit 8
R/W-0
R/W-0
R/W-0
U-0
U-0
R/W-0
R/W-0, HSC
R-0, HSC
SSRC2
SSRC1
SSRC0
ASAM
SAMP
DONE
bit 7
bit 0
Legend:
HSC = Hardware Settable/Clearable bit
R = Readable bit
W = Writable bit
U = Unimplemented bit, read as ‘0’
-n = Value at POR
‘1’ = Bit is set
‘0’ = Bit is cleared
x = Bit is unknown
bit 15
ADON:
 A/D Operating Mode bit
(
)
1
 = A/D Converter module is operating
0
 = A/D Converter is off
bit 14
Unimplemented:
 Read as ‘0’
bit 13
ADSIDL:
 Stop in Idle Mode bit
1
 = Discontinue module operation when device enters Idle mode
0
 = Continue module operation in Idle mode
bit 12-10
Unimplemented:
 Read as ‘0’
bit 9-8
FORM<1:0>:
 Data Output Format bits
11
 = Signed fractional (sddd dddd dd00 0000)
10
 = Fractional (dddd dddd dd00 0000)
01
 = Signed integer (ssss sssd dddd dddd)
00
 = Integer (0000 00dd dddd dddd)
bit 7-5
SSRC<2:0>:
 Conversion Trigger Source Select bits
111
 = Internal counter ends sampling and starts conversion (auto-convert)
110
 = Reserved
101
 = Reserved
100
 = Reserved
011
 = Reserved
010
 = Timer1 compare ends sampling and starts conversion
001
 = Active transition on INT0 pin ends sampling and starts conversion
000
 = Clearing the SAMP bit ends sampling and starts conversion
bit 4-3
Unimplemented:
 Read as ‘0’
bit 2
ASAM:
 A/D Sample Auto-Start bit
1
 = Sampling begins immediately after the last conversion completes; SAMP bit is auto-set
0
 = Sampling begins when the SAMP bit is set
bit 1
SAMP:
 A/D Sample Enable bit
1
 = A/D sample/hold amplifier is sampling input
0
 = A/D sample/hold amplifier is holding
bit 0
DONE:
 A/D Conversion Status bit
1
 = A/D conversion is done
0
 = A/D conversion is not done
Note 1:
Values of ADC1BUFx registers will not retain their values once the ADON bit is cleared. Read out the 
conversion values from the buffer before disabling the module.