Microchip Technology DM160218 Data Sheet

Page of 46
 2012-2013 Microchip Technology Inc.
Advance Information
DS40001667C-page 19
MGC3130
FIGURE 4-7:
CURRENT CONSUMPTION FOR VARYING TIME INTERVALS BETWEEN 
APPROACH SCANS AND CALIBRATION SCANS
FIGURE 4-8:
CURRENT CONSUMPTION FOR A FIXED TIME INTERVAL BETWEEN 
APPROACH SCANS OF 20 ms
0,11
0,77
0,57
1,21
0,20
0,86
0,00
0,20
0,40
0,60
0,80
1,00
1,20
1,40
0
50
100
150
200
Cur
rent Consumption 
[mA
]
Time Interval between Approach Scans[ms]
no Calibration Scan
Calibration Scan every 2s
Calibration Scan every 10s
1,21
1,07
0,99
0,95
0,92
0,90
0,88
0,87
0,86
0,00
0,20
0,40
0,60
0,80
1,00
1,20
1,40
0
2
4
6
8
10
12
Cur
rent Consumption 
(mA
)
Time interval between Calibration Scans (s)