14  Voltages 
14.1  Menu: Options 
→ Voltage 
 
 
14.2  Vdd Source and LVP Mode 
The programmer executes operations at the following Vdd voltages 
 
### 
Vdd Source  LVP 
Mode 
Vdd during 
Programming 
Vdd during 
Verify 
Vdd during 
Blank 
Check 
Vdd during 
Read 
1.   
Programmer  Normal 
Database 
VddMin, 
VddMax 
(Note 2) 
VddMin 
Database 
2.   
Programmer  LVP 
VddMax 
 (Note 1) 
VddMax 
VddMax 
VddMax 
3.   
Target 
Normal 
Target 
Target 
Target 
Target 
 
Notes:  
1) Use LVP mode if you want to change default programming voltage 
2) Set VddMin=VddMax to disable the 2-nd verification pass 
14.3  Vpp Voltage 
The Vpp voltage is the same for all the operations 
14.4  Vdd-to-Vpp Delay 
Delay between Vdd and Vpp can be in range 0.1...250ms. It is recommended to use default delay of 4ms to 
correctly enter the programming mode. Longer delays may be useful if the Vdd line has high capacitance 
(more than 200uF) which causes the Vdd to rise slowly  
14.5  ICP-01 Compatibility 
Press on “ICP-01 compatible” button forces the following settings: 
- Vdd Source:   
 
Programmer 
- LVP Mode: 
 
 
Normal 
- Voltages: 
 
 
Database values