22  Manual Production Mode (One-Touch Operation) 
The production mode is a powerful option for volume programming 
 
The following steps should be done to correctly prepare the software for programming in the production 
mode: 
 
 
Create a subdirectory (C:\FILE_HEX) 
 
Copy your CFG, HEX and SERIALIZATION files to FILE_HEX subdirectory (for example: "hex1.hex" and 
"ser1.ser") 
NOTE: serialization file is optional 
 
Change ICP_Win shortcut property "Start in" to C:\FILE_HEX 
 
Change ICP_Win shortcut property "Target" to C:\...\ICP_Win.exe hex1.hex /sser1.ser /p 
 
Double-click ICP_Win icon for programming 
 
The program will be terminated in the following cases: 
 
Communication error 
 
Hex file error 
 
Serialization file should be loaded (/s appears) but loading is failed 
 
23  In-Circuit Programming 
Standard in-circuit programming is done through 5 wires (VDD, GND, CLOCK, DATA and VPP) 
23.1  Vdd 
 
Maximum Vdd current consumption by the application circuit :  
- ICP2/ICP2-GANG:  
  250mA  
- ICP2(HC):  
 
1000mA 
- ICP2-Portable: 
 
    50mA  
 
 
Maximum Vdd capacitance: 1000-10000uF. For ICP2/ICP2-GANG, increase Vdd-to-Vpp delay by about 
20ms for every 1000uF  
 
NOTE: If your circuit has low current consumption (less than 10mA) in conjunction with high capacitance 
(more than 100uF), the load resistor (100-510 Ohm) must be connected between Vdd and GND pins of the 
programmer for faster discharge of Vdd capacitor 
23.2  Vpp 
Vpp recommended load (ICP2/ICP2GANG/ICP2-Portable): 
 
 
> 1KOhm,   < 33nF 
Vpp recommended load (ICP2(HC)): 
 
 
 
 
 
> 100 Ohm, <100nF 
23.3  CLOCK and DATA 
CLOCK and DATA recommended load(ICP2/ICP2GANG/ICP2-Portable):  
> 3.3KOhm, < 33pF 
CLOCK and DATA recommended load(ICP2(HC)): 
 
 
 
> 50 Ohm,    < TBD nF 
23.4  Delay between Vdd and Vpp 
This delay should be as short as possible (4ms is recommended) 
 
NOTE: for more details contact Softlog Systems to obtain 
“ICP2-GANG Specification”“ICP2 
Specification”, “ICP2(HC) Specification” and “ICP2-Portable Specification”