1.4.3
Heating Element
A resistor is used as a heating element to generate heat near the MCP9700 tempera-
ture sensor to simulate a thermal system. To activate the heating element, set the 
CTRL line (RA3) high. Once, the heating element is active, the ON LED will light up. In 
order to operate the heating element, JP200, heater enable jumper, must be in place.
1.4.4
Board Options
The PICDEM™ System Management Board is scribed and can be separated into two 
separate boards.
The fan control board contains the connectors for two, three and four-wire fans in addi-
tion to the control, power and ground lines for the heating element and temperature 
sensor, as well as the fan drive circuitry.
The main board contains the PIC16F866, power input, push-buttons, LEDs, battery 
backup circuit and connectors that break out the fan control, temperature sensor and 
heating element pins. These elements can be used in conjunction with the prototyping 
area for development. 
1.5
QUICK START GUIDE
The PICDEM™ System Management Board is preloaded with demonstration firmware. 
The board must be configured as described in this section in order to use the 
demonstration program. For details on firmware, please review the System 
Management presentation included on the CD-ROM.
Board Setup
1.
Connect the 3-wire fan to the 3-wire fan connector labeled “3-wire”.
2.
Place the JP201 jumper on the bottom setting, connecting “TACH” to the middle 
pin.
3.
Connect the J200 jumper to allow the heating element to be turned on. 
4.
Plug the PICkit Serial Analyzer into the PICDEM System Management Board on 
the pins marked “PICkit Serial” (P104).
5.
Plug the PICkit Serial Analyzer USB cable into a compatible PC.
Board Power-Up
Connect the provided +12V power supply to J100.
1.5.1
Demonstration Program
1.
Insert the included PICDEM System Management CD into the CD drive.
2.
Run the installation software for the PICDEM System Management GUI 
(D:\Setup\Setup.exe).
3.
Run the System Management program (start <Programs<Microchip System 
Management Board). 
Within this screen there are several tabs that allow control and monitoring of various 
functions.
WARNING
The heating element will be very hot when on. Do not activate the heating ele-
ment unless the fan is running. Always disconnect JP200 after use and allow 
the heating element to cool.