Microchip Technology DM300018 User Manual

Page of 115
Using the dsPIC30F3010
© 2005 Microchip Technology Inc.
DS51558A-page 41
6.4
DEVICE PROGRAMMING
Load the sample application program for the dsPIC30F3010 using this process:
1.
Plug the RJ11 (telephone) cable from the MPLAB ICD 2 into the ICD header (J1). 
Make sure the USB cable from the MPLAB ICD 2 is connected to your PC.
2.
Start MPLAB IDE.
3.
Open the dsPIC30F3010 sample project (
File>Open Workspace) from 
path/dsPICDEM 2 Development Kit/Example Soft-
ware/30F3010/Demo.mcw
.
4.
Build the sample project in MPLAB IDE (
Project>Build All).
5.
On the dsPICDEM™ 2 board set all positions on switch S4 to off. Then set switch 
S2 to M ALL. The MPLAB ICD 2 is now connected to the PGC and PGD pins on 
the dsPIC30F3010.
6.
Download the sample application (
Programmer>Program). The Output window 
(Figure 6-2) displays the status as the download occurs and indicates when the 
programming has succeeded.
FIGURE 6-2:
PROGRAMMING THE dsPIC30F3010 DEVICE
7.
Disconnect the MPLAB ICD 2 cable from the ICD header. The program is now 
ready to run (see Section 6.5 “Observing the Sample Application”).
Note:
For detailed information and procedures on using the MPLAB IDE and ICD 
2, refer to Chapter 2 “Getting Started”.