Microchip Technology AC164337 Data Sheet
dsPIC30F1010/202X
DS70000178D-page 180
2006-2014 Microchip Technology Inc.
bit 4-0
TRGSRC4<4:0>: Trigger Source Selection 4 bits
Selects trigger source for conversion of analog channels: AN9 and AN8
Selects trigger source for conversion of analog channels: AN9 and AN8
00000
= No conversion enabled
00001
= Individual software trigger selected
00010
= Global software trigger selected
00011
= PWM Special Event Trigger selected
00100
= PWM generator #1 trigger selected
00101
= PWM generator #2 trigger selected
00110
= PWM generator #3 trigger selected
00111
= PWM generator #4 trigger selected
01100
= Timer #1 period match
01101
= Timer #2 period match
01110
= PWM GEN #1 current-limit ADC trigger
01111
= PWM GEN #2 current-limit ADC trigger
10000
= PWM GEN #3 current-limit ADC trigger
10001
= PWM GEN #4 current-limit ADC trigger
10110
= PWM GEN #1 fault ADC trigger
10111
= PWM GEN #2 fault ADC trigger
11000
= PWM GEN #3 fault ADC trigger
11001
= PWM GEN #4 fault ADC trigger
REGISTER 16-7:
A/D CONVERT PAIR CONTROL REGISTER 2 (ADCPC2) (CONTINUED)