Microchip Technology MCP3421EV Data Sheet

Page of 42
MCP3421
DS22003E-page 24
© 2009 Microchip Technology Inc.
TABLE 5-4:
I
2
C SERIAL TIMING SPECIFICATIONS
Electrical Specifications: Unless otherwise specified, all limits are specified for T
A
 = -40 to +85°C,
V
IN
+ = V
IN
- = V
REF
/2,  V
SS
 = 0V, V
DD
 = +2.7V to +5.0V.
Parameters
Sym
 Min
 Typ
 Max
Units
           Conditions
Standard Mode (100 kHz)
Clock frequency
f
SCL
100
kHz
Clock high time
THIGH
4000
ns
Clock low time
TLOW
4700
ns
SDA and SCL rise time
TR
1000
ns
From V
IL
 to V
IH
SDA and SCL fall time
TF
300
ns
From V
IH
 to V
IL 
START condition hold time
THD:STA
4000
ns
START (Repeated) condition 
setup time
TSU:STA
4700
ns
Data hold time 
THD:DAT
0
3450
ns
(
Data input setup time
TSU:DAT
250
ns
STOP condition setup time
TSU:STO
4000
ns
Output valid from clock
TAA
0
3750
ns
(
Bus free time
TBUF
4700
ns
Time between START and 
STOP conditions. 
Fast Mode (400 kHz)
Clock frequency
TSCL
400
kHz
Clock high time
THIGH
600
ns
Clock low time
TLOW
1300
ns
SDA and SCL rise time
TR
20 + 0.1Cb
300
ns
From V
IL
 to V
IH 
SDA and SCL fall time 
TF
20 + 0.1Cb
300
ns
From V
IH
 to V
IL 
START condition hold time
THD:STA
600
ns
START (Repeated) condition 
setup time
TSU:STA
600
ns
Data hold time 
THD:DAT
0
900
ns
(
Data input setup time
TSU:DAT
100
ns
STOP condition setup time
TSU:STO
600
ns
Output valid from clock
TAA
0
1200
ns
(
Bus free time
TBUF
1300
ns
Time between START and 
STOP conditions. 
Note 1: This parameter is ensured by characterization and not 100% tested.
2: This specification is not a part of the I
2
C specification. This specification is equivalent to the Data Hold 
Time (T
HD:DAT
) plus SDA Fall (or rise) time: T
AA
 = T
HD:DAT
 + T
F
 (
OR
 T
R
).
3: If this parameter is too short, it can create an unintended Start or Stop condition to other devices on the 
bus line. If this parameter is too long, Clock Low time (T
LOW
) can be affected. 
4: For Data Input: This parameter must be longer than t
SP
. If this parameter is too long, the Data Input Setup 
(T
SU:DAT
) or Clock Low time (T
LOW
) can be affected.
For Data Output: This parameter is characterized, and tested indirectly by testing T
AA
 parameter.