TABLE 24-38: I2Cx BUS DATA TIMING REQUIREMENTS (MASTER MODE)
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature
-40°C 
 T
A
 
 +85°C for Industrial
-40°C 
 T
A
 
 +125°C for Extended 
Param
No.
Symbol
Characteristic
Min
(
)
Max
Units
Conditions
IM10
T
LO
:
SCL
Clock Low Time 100 kHz mode
T
CY
/2 (BRG + 1)
s
400 kHz mode
T
CY
/2 (BRG + 1)
s
1 MHz mode
(
)
T
CY
/2 (BRG + 1)
s
IM11
T
HI
:
SCL
Clock High Time  100 kHz mode
T
CY
/2 (BRG + 1)
s
400 kHz mode
T
CY
/2 (BRG + 1)
s
1 MHz mode
(
)
T
CY
/2 (BRG + 1)
s
IM20
T
F
:
SCL
SDAx and SCLx
Fall Time
100 kHz mode 
300
ns
C
B
 is specified to be 
from 10 pF to 400 pF
400 kHz mode
20 + 0.1 C
B
300
ns
1 MHz mode
(
)
100
ns
IM21
T
R
:
SCL
SDAx and SCLx
Rise Time
100 kHz mode 
1000
ns
C
B
 is specified to be 
from 10 pF to 400 pF
400 kHz mode
20 + 0.1 C
B
300 ns
1 MHz mode
(
)
300
ns
IM25
T
SU
:
DAT
Data Input
Setup Time
100 kHz mode
250 
ns
400 kHz mode
100 
ns
1 MHz mode
(
)
40 —
ns
IM26
T
HD
:
DAT
Data Input
Hold Time
100 kHz mode
0
s
400 kHz mode
0
0.9
s
1 MHz mode
(
)
0.2 —
s
IM30
T
SU
:
STA
Start Condition
Setup Time
100 kHz mode
T
CY
/2 (BRG + 1)
s
Only relevant for 
Repeated Start
condition
400 kHz mode
T
CY
/2 (BRG + 1)
s
1 MHz mode
(
)
T
CY
/2 (BRG + 1)
s
IM31
T
HD
:
STA
Start Condition 
Hold Time 
100 kHz mode
T
CY
/2 (BRG + 1)
s
After this period the
first clock pulse is
generated
400 kHz mode
T
CY
/2 (BRG + 1)
s
1 MHz mode
(
)
T
CY
/2 (BRG + 1)
s
IM33
T
SU
:
STO
Stop Condition 
Setup Time
100 kHz mode
T
CY
/2 (BRG + 1)
s
400 kHz mode
T
CY
/2 (BRG + 1)
s
1 MHz mode
(
)
T
CY
/2 (BRG + 1)
s
IM34
T
HD
:
STO
Stop Condition
100 kHz mode
T
CY
/2 (BRG + 1)
ns
Hold Time
400 kHz mode
T
CY
/2 (BRG + 1)
ns
1 MHz mode
(
)
T
CY
/2 (BRG + 1)
ns
IM40
T
AA
:
SCL
Output Valid 
From Clock
100 kHz mode
3500 
ns
400 kHz mode
1000 
ns
1 MHz mode
(
)
400
ns
IM45
T
BF
:
SDA
Bus Free Time
100 kHz mode
4.7 
s
Time the bus must be 
free before a new
transmission can start
400 kHz mode
1.3 
s
1 MHz mode
(
)
0.5
s
IM50
C
B
Bus Capacitive Loading
 400 
pF 
IM51
T
PGD
Pulse Gobbler Delay
65
390
ns
See Note 
Note 1:
BRG is the value of the I
2
C™ Baud Rate Generator. Refer to “Inter-Integrated Circuit (I
2
C™)” 
(DS70000195) in the “dsPIC33/PIC24 Family Reference Manual”.
2:
Maximum pin capacitance = 10 pF for all I2Cx pins (for 1 MHz mode only).
3:
Typical value for this parameter is 130 ns.