Microchip Technology DM164130-7 Data Sheet

Page of 60
F1 LV Evaluation Platform Motor Control Add-ons
DS41629A-page 16
 2012 Microchip Technology Inc.
FIGURE 1-2:

19
20
21
33
32
22
23
25
26
27
24
28
29
31
30
19. BLDC flyback voltage blanking time.
20. BLDC dwell time at each start-up step.
21. BLDC milliseconds to remain in Open-Loop 
mode at start-up before closing the loop.
22. BLDC minimum commutation time below 
which a stall is detected.
23. BLDC error feedback multiplication factor. 
Each shift divides error by 2.
24. Stepper motor steps in each drive phase 
when microstepping is selected.
25. Button to invoke new microstep sinusoid 
drive look-up table.
26. Peak drive level in microstep look-up table.
27. Stepper motor commutation mode selec-
tion.
28. Stepper motor maximum RPM commutation 
rate when speed control is set at maximum. 
29. Degrees per step physical attribute of the 
attached motor.
30. Maximum drive voltage duty cycle applied 
when speed control is at the maximum 
RPM. This prevents excessive overdrive of 
the motor.
31. Stepper motor drive voltage duty cycle 
applied when speed control is at the lowest 
run speed above stop.
32. Percent of speed control setting, relative to 
maximum, below which the motor drive is 
removed and the motor is stopped.
33. Percent of speed control setting, relative to 
maximum, above which the motor starts 
from a stopped state.