Ansmann AA battery (rechargeable) NiMH AA maxE 6+2 free 2100 mAh 1.2 V 8 pc(s) 1322-0001-510 Data Sheet

Product codes
1322-0001-510
Page of 1
Conditions
  cell type:
NiMH
  cell size:
AA
  nominal voltage:
1.2
V
  max. charge voltage:
1.5
V
at standard charge
(0.1C / 20°C)
  capacity
  nominal:
2100
mAh
discharge at 0.2C
  minimum:
1900
mAh
discharge at 0.2C
1750
mAh
discharge at 1C
1.0V end discharge voltage
ta: 20°C
  max. continuous
  discharge current:
4200
mA
ta: 0....45°C
  charge
current
time
  standard charge:
210
mA
14....16hrs
  quick charge:
600
mA
4hrs
  fast charge:
1400
mA
1.7hrs
  recommended charge 
5...10
mV
- delta V
  termination control
0.8...1
°C
temp. increase per minute
  parameters:
45...50
°C
TCO (temperature cut off)
  trickle charge current:
21...105 mA
(recommended)
  continuous overcharge:
 190
mA
no conspicuous deformation
  (less than 1 year)
no leakage
  internal resistance:
 40
m
Ω
at 1KHz
  (impedance)
battery fully charged
  life expectance:
 500
cycles acc. IEC standard
  self discharge
  charge retention:
 75
%
after 12 months
storage at 20°C
  initial capacity:
 1350
mAh
within 30 days after delivery
discharge at 0.2C
  ambient temperature
  range:
  0...45
°C
standard charge
10...40
°C
fast charge
- 20...65
°C
discharge (
1.0C)
  0...45
°C
discharge (>1.0C)
- 20...50
°C
storage (
3months)
- 20...40
°C
storage (
6months)
- 20...30
°C
storage (
24months)
  QCT1:
20/1800/40
  QCT2:
30/1650/45
  mechanical specifications
  cell dimensions (incl. label)
  diameter d1:
14.3  - 0.5 mm
  diameter d2:
max.
5.5
mm
  height h1:
50.3  - 0.5 mm
  height h2:
min.
1.2
mm
  weight:
28
± 2
g
  dimensions shrink pack:
115 x 51 x 14.5 mm
  weight shrink pack:
225
g
27
Manufacturer reserves the right to alter or amend the design, model and specification without prior notice
 ANSMANN Specifications for model:
 data sheet no. / part no.
 version no.
 author / date
AA - 2100mAh   ANSMANN   maxE                     
6+2 pcs. shrink package
1322-0001-510
Diagrams
standard charge
fast charge
low rate discharge
high rate discharge
0