b) Stopwatch function
•  Press the ST/STP (3) key to start the stopwatch.
•  Press the ST/STP (3) key to stop the stopwatch.
•  With the ST/STP (3) key, the stopwatch can be restarted. 
•  Press the RESET (1) key after you have stopped the stopwatch to reset the stop-
watch to “0:00:00”.
•  While the stopwatch is running you can display a split time by pressing the RESET 
(1) key. The display indicates the split time but the stopwatch continues to run in the 
background.
•  Press the RESET key (1) again to return to the stopwatch display.
c) Countdown Timer
Setting the time target
•  Press the RESET key (1).
•  Use the ST/STP key (3) to set the hour target.
•  Press the MODE key (2) to switch to the next setting step (minutes).
•  Use the ST/STP key (3) to set the minute target.
•  Press the MODE key (2) to switch to the next setting step (seconds).
•  Use the ST/STP key (3) to set the second target.
•  Press the RESET key (1) to save the time target.
Use of the countdown timer
•  Press the ST/STP (3) key to start the countdown timer.
•  Press the ST/STP (3) key again to interrupt the countdown timer or to restart it. 
•  When the preset time has passed, an acoustic signal is emitted for approx. 60 sec-
onds.
•  Press any key to turn the acoustic signal off.
d) Alarm function
Activate or deactivate the alarm function
•  Press the LIGHT (4) key to select the desired function (hour signal or alarm 1-5).
•  To activate or deactivate the hour signal or the selected alarm, press the ST/STP 
(3) key. With activated hour signal, a bell icon appears on the right bottom of the 
display. With activated alarm, an alarm symbol appears.
•  At the set alarm time an alarm sound is emitted for approx. 60 seconds. Press any 
key to turn the alarm sound off.
Alarm time setting
•  Select the alarm function to be set (alarm 1-5) using the LIGHT (4) key.
•  Press the RESET key (1) to select the hour display.
•  Use the ST/STP key (3) to set the hour display.
•  Press the MODE key (2) to select minute display. 
•  Use the ST/STP key (3) to set the minute display.
•  Press the RESET key (1) to save the setting.
e) Time of the second time zone
•  Press the RESET key (1) to select the hour display.
•  Use the ST/STP key (3) to set the hour display.
•  Press the MODE key (2) to select minute display.
•  Use the ST/STP key (3) to set the minute display. The minute display is changed in 
30-minute steps.
•  Press the RESET key (1) to save the setting.
f) Pacer function
•  Press the RESET (1) key to set the number of acoustic signals per minute (10, 20, 30, 
40, 60, 80, 120, 160, 240 or 320).
•  Press the ST/STP (3) key to start the pacer function.
•  Press the ST/STP (3) key to stop the pacer function again.
Illumination
•  Press the LIGHT key (4) to turn on the clock face light for a few seconds.
Battery Notes
•  Batteries should be kept out of the reach of children.
•  Do not leave batteries lying around in the open; there is a risk of them being swal-
lowed by children or pets. If they are swallowed, consult a doctor immediately.
•  Leaking or damaged batteries can lead to caustic burning of the skin. Therefore, use 
suitable protective gloves. 
•  Batteries must not be short-circuited, opened or thrown into a fire. There is a risk of 
explosion!
•  Do not recharge normal, non-rechargeable batteries, due to risk of explosion! Only 
charge  rechargeable  batteries  that  are  intended  for  this  purpose;  use  a  suitable 
battery charger.
•  Please pay attention to the correct polarity (plus/+ and minus/-) when inserting the 
battery.
Changing the Batteries
•  If the display does not show anything, the battery has to be replaced.
•  Replacing the battery should be done by a specialist, using special clockmaker tools 
and professional knowledge.
•  To replace the battery, the bottom of the casing is removed.
•  The battery can then be removed from its holder and be replaced.
Water and Shock Resistance
In normal use, the wristwatch is protected against shocks. Nevertheless, do not ex-
pose the device to extreme shocks such as it might occur if the device falls onto a hard 
surface. This might damage the watch mechanism.
The  labelling  10  ATM  means  that  the  watch  is  suitable  for  bathing,  swimming,  car 
wash, showering and so on.
It is not a diver’s watch. Never press the buttons under water.
Maintenance and cleaning
To clean the watch, a dry, soft and clean cloth is sufficient. For heavier soiling of the 
exterior, you can moisten the cloth slightly with lukewarm water.
Clean the watch very carefully; otherwise you may scratch it.
Do not press too heavily on the glass cover, as this can lead to breakage
Disposal
a) Product
  Electronic devices are recyclable waste materials and must not be disposed 
of in the household waste!
 
Dispose of an unserviceable product in accordance with the relevant statu-
tory regulations.
 
Remove the battery if there is one inserted and dispose of it separately from 
the product.
b) Normal and Rechargeable Batteries
As the end user, you are required by law (Battery Regulation) to return used batteries 
and rechargeable batteries. Do not dispose of used batteries in the household waste!
  Batteries/rechargeable batteries contain harmful materials and are labelled 
with  the  symbol  shown  to  indicate  that  disposal  in  the  household  waste 
is forbidden. The symbols of the relevant heavy metals are: Cd=cadmium, 
Hg=mercury,  Pb=lead  (marking  can  be  seen  on  the  battery/rechargeable 
battery, e.g. underneath the refuse bin symbol shown on the left).
You can return your used batteries/rechargeable batteries free of charge at the official 
collection  points  of  your  community,  in  our  stores,  or  at  places  where  batteries  or 
rechargeable batteries are sold!
You  thereby  fulfil  your  statutory  obligations  and  contribute  to  the  protection  of  the 
environment.
Technical data
Operating voltage............................... 3 V/DC
Battery  1 x lithium coin cell ............. CR2025
Battery life   ......................................... approx. 2 years
Water-tightness .................................. 10 ATM
Weight .................................................. 65 g