Hycell AA battery (rechargeable) NiMH HR06 1000 mAh 1.2 V 4 pc(s) 1312-0008 Data Sheet

Product codes
1312-0008
Page of 1
Conditions
  cell type:
NiMH
  cell size:
AA
  nominal voltage:
1.2
V
  max. charge voltage:
1.5
V
at standard charge
(0.1C / 20°C)
  capacity
  nominal:
1000
mAh
discharge at 0.2C
  minimum:
800
mAh
discharge at 0.2C
750
mAh
discharge at 1C
1.0V end discharge voltage
ta: 20°C
  max. continuous
  discharge current:
2400
mA
ta: 0....45°C
  charge
current
time
  standard charge:
100
mA
14....16hrs
  quick charge:
250
mA
4hrs
  fast charge:
1000
mA
1hr
  recommended charge 
0…5
mV
V (-deltaV)
  termination control
0.8...1
°C
temperature rise per minute
  parameters:
45...50
°C
TCO (temperature cut off)
  trickle charge current:
5…25
mA
(recommended)
  continuous overcharge:
 80
mA
no conspicuous deformation
  (less than 1 year)
no leakage
  internal resistance:
 50
m
Ω
at 1KHz
  (impedance)
battery fully charged
  life expectance:
 500
cycles acc. IEC standard
  self discharge
  charge retention:
 80
%
after 12 months
storage at 20°C
  initial capacity:
 550
mAh
within 30 days after delivery
discharge at 0.2C
  ambient temperature
  range:
  0...45
°C
standard charge
10...40
°C
fast charge
  0...45
°C
discharge (
1C)
- 20...65
°C
discharge (<1C)
- 20...50
°C
storage (
3months)
- 20...40
°C
storage (
6months)
- 20...30
°C
storage (
24months)
  QCT1:
20/750/50
  QCT2:
30/700/55
  mechanical specifications
  cell dimensions
  diameter d1:
14.3 - 0.7
mm
  diameter d2:
max.
5.5
mm
  height h1:
50.4 - 0.5
mm
  height h2:
min.
1.2
mm
  weight:
17 ± 2
g
  blister card dimensions:
123 x  85
mm
  blister card weight (incl. batteries):
76
g
75
Diagrams
standard charge
fast charge
Manufacturer reserves the right to alter or amend the design, model and specification without prior notice
 ANSMANN Specifications for model:
 data sheet no. / part no.
 supplier no.
 author / date
AA - 1000mAh   low self discharge       
HyCell        4pcs blister package
Gramlich / 28.03.2012
1312-0008
702069
low rate discharge
high rate discharge