Microchip Technology MA330016 Data Sheet

Page of 300
© 2007-2011 Microchip Technology Inc.
DS70290J-page 245
dsPIC33FJ32GP202/204 and dsPIC33FJ16GP304
 
TABLE 22-37: I2Cx BUS DATA TIMING REQUIREMENTS (SLAVE MODE)
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature -40°C 
≤ T
A
 
≤ +85°C for Industrial
-40°C 
≤ T
A
 
≤ +125°C for Extended
Param Symbol
Characteristic
(2)
Min
Max
Units
Conditions
IS10
T
LO
:
SCL
Clock Low Time
100 kHz mode
4.7
μs
Device must operate at a 
minimum of 1.5 MHz
400 kHz mode
1.3
μs
Device must operate at a 
minimum of 10 MHz
1 MHz mode
(1)
0.5
μs
IS11
T
HI
:
SCL
Clock High Time
100 kHz mode
4.0
μs
Device must operate at a 
minimum of 1.5 MHz
400 kHz mode
0.6
μs
Device must operate at a 
minimum of 10 MHz
1 MHz mode
(1)
0.5
μs
IS20
T
F
:
SCL
SDAx and SCLx
Fall Time
100 kHz mode 
300
ns
C
B
 is specified to be from
10 to 400 pF
400 kHz mode
20 + 0.1 C
B
300
ns
1 MHz mode
(1)
100
ns
IS21
T
R
:
SCL
SDAx and SCLx
Rise Time
100 kHz mode 
1000
ns
C
B
 is specified to be from
10 to 400 pF
400 kHz mode
20 + 0.1 C
B
300
ns
1 MHz mode
(1)
300
ns
IS25
T
SU
:
DAT
Data Input
Setup Time
100 kHz mode
250
ns
400 kHz mode
100
ns
1 MHz mode
(1)
100
ns
IS26
T
HD
:
DAT
Data Input
Hold Time
100 kHz mode 
0
μs
400 kHz mode
0
0.9
μs
1 MHz mode
(1)
0
0.3
μs
IS30
T
SU
:
STA
Start Condition
Setup Time
100 kHz mode
4.7
μs
Only relevant for Repeated 
Start condition
400 kHz mode
0.6
μs
1 MHz mode
(1)
0.25
μs
IS31
T
HD
:
STA
Start Condition 
Hold Time 
100 kHz mode
4.0
μs
After this period, the first 
clock pulse is generated
400 kHz mode
0.6
μs
1 MHz mode
(1)
0.25
μs
IS33
T
SU
:
STO
Stop Condition 
Setup Time
100 kHz mode
4.7
μs
400 kHz mode
0.6
μs
1 MHz mode
(1)
0.6
μs
IS34
T
HD
:
ST
O
Stop Condition
Hold Time
100 kHz mode 
4000
ns
400 kHz mode
600
ns
1 MHz mode
(1)
250
ns
IS40
T
AA
:
SCL
Output Valid 
From Clock
100 kHz mode
0
3500
ns
400 kHz mode
0
1000
ns
1 MHz mode
(1)
0
350
ns
IS45
T
BF
:
SDA
Bus Free Time
100 kHz mode
4.7
μs
Time the bus must be free 
before a new transmission 
can start
400 kHz mode
1.3
μs
1 MHz mode
(1)
0.5
μs
IS50
C
B
Bus Capacitive Loading
 400
pF 
Note 1: Maximum pin capacitance = 10 pF for all I2Cx pins (for 1 MHz mode only).