Microchip Technology AC244045 Data Sheet

Page of 448
 2010-2012 Microchip Technology Inc.
DS41440C-page 283
PIC16(L)F1825/1829
FIGURE 25-34:
BUS COLLISION DURING START CONDITION (SCLX = 0)      
FIGURE 25-35:
BRG RESET DUE TO SDA ARBITRATION DURING START CONDITION        
SDAx
SCLx
SEN
bus collision occurs. Set BCLxIF.
SCLx = 0 before SDAx = 0,
Set SEN, enable Start
sequence if SDAx = 1, SCLx = 1
T
BRG
T
BRG
SDAx = 0, SCLx = 1
BCLxIF
S
SSPxIF
Interrupt cleared
by software
bus collision occurs. Set BCLxIF.
SCLx = 0 before BRG time-out,
’0’
’0’
’0’
’0’
SDAx
SCLx
SEN
Set S
Less than T
BRG
T
BRG
SDAx = 0, SCLx = 1
BCLxIF
S
SSPxIF
S
Interrupts cleared
by software
set SSPxIF
SDAx = 0, SCLx = 1,
SCLx pulled low after BRG
time out
Set SSPxIF
‘0’
SDAx pulled low by other master.
Reset BRG and assert SDAx.
Set SEN, enable Start
sequence if SDAx = 1, SCLx = 1