Microchip Technology AC244045 Data Sheet
2010-2012 Microchip Technology Inc.
DS41440C-page 367
PIC16(L)F1825/1829
TABLE 30-8:
PIC16(L)F1825/1829 A/D CONVERTER (ADC) CHARACTERISTICS
(1,2,3)
TABLE 30-9:
PIC16(L)F1825/1829 A/D CONVERSION REQUIREMENTS
Standard Operating Conditions (unless otherwise stated)
Operating temperature
Operating temperature
-40°C
T
A
+125°C
Param
No.
Sym.
Characteristic
Min.
Typ†
Max. Units
Conditions
AD01
N
R
Resolution
—
—
10
bit
AD02
E
IL
Integral Error
—
—
±1.7
LSb V
REF
= 3.0V
AD03
E
DL
Differential Error
—
—
±1
LSb No missing codes
V
REF
= 3.0V
AD04
E
OFF
Offset Error
—
—
±2.5
LSb V
REF
= 3.0V
AD05
E
GN
Gain Error
—
—
±2.0
LSb V
REF
= 3.0V
AD06
V
REF
Reference Voltage
(4)
1.8
—
V
DD
V
V
REF
= (V
REF
+ minus V
REF
-)
AD07
V
AIN
Full-Scale Range
V
SS
—
V
REF
V
AD08
Z
AIN
Recommended Impedance of
Analog Voltage Source
Analog Voltage Source
—
—
10
k
Can go higher if external 0.01F capacitor is
present on input pin.
†
Data in “Typ” column is at 3.0V, 25°C unless otherwise stated. These parameters are for design guidance only and are not
tested.
tested.
Note 1: Total Absolute Error includes integral, differential, offset and gain errors.
2: The A/D conversion result never decreases with an increase in the input voltage and has no missing codes.
3: ADC V
3: ADC V
REF
is from external V
REF
, V
DD
pin or FVR, whichever is selected as reference input.
4: ADC Reference Voltage (
REF
+) is the selected input, V
REF
+ pin, V
DD
pin or the FVR Buffer1. When the FVR is selected as
the reference input, the FVR Buffer1 output selection must be 2.048 or 4.096V (ADFVR<1:0> = 1x).
Standard Operating Conditions (unless otherwise stated)
Operating temperature
Operating temperature
-40°C
T
A
+125°C
Param
No.
Sym.
Characteristic
Min.
Typ†
Max.
Units
Conditions
AD130* T
AD
A/D Clock Period
1.0
—
9.0
s
T
OSC
-based
A/D Internal RC Oscillator
Period
Period
1.0
2.5
6.0
s
ADCS<1:0> = 11 (ADRC mode)
AD131
T
CNV
Conversion Time (not including
Acquisition Time)
Acquisition Time)
(1)
—
11
—
T
AD
Set GO/DONE bit to conversion
complete
complete
AD132* T
ACQ
Acquisition Time
—
5.0
—
s
*
These parameters are characterized but not tested.
†
Data in “Typ” column is at 3.0V, 25°C unless otherwise stated. These parameters are for design guidance only and are not
tested.
tested.
Note 1: The ADRES register may be read on the following T
CY
cycle.