Microchip Technology MA160014 Data Sheet

Page of 560
PIC18(L)F2X/4XK22
DS41412F-page 434
 2010-2012 Microchip Technology Inc.
D030
0.35
0.50
mA
-40°C to +125°C
V
DD
 = 1.8V
F
OSC
 = 1 MHz
(RC_RUN mode, 
HFINTOSC 
source)
D031
0.45
0.65
mA
-40°C to +125°C
V
DD
 = 3.0V
D032
0.40
0.60
mA
-40°C to +125°C
V
DD
 = 2.3V
F
OSC
 = 1 MHz
(RC_RUN mode, 
HFINTOSC 
source)
D033
0.50
0.65
mA
-40°C to +125°C
V
DD
 = 3.0V
D034
0.55
0.75
mA
-40°C to +125°C
V
DD
 = 5.0V
D035
1.3
2.0
mA
-40°C to +125°C
V
DD
 = 1.8V
F
OSC
 = 16 MHz
(RC_RUN mode, 
HFINTOSC 
source)
D036
2.2
3.0
mA
-40°C to +125°C
V
DD
 = 3.0V
D037
1.7
2.0
mA
-40°C to +125°C
V
DD
 = 2.3V
F
OSC
 = 16 MHz
(RC_RUN mode, 
HFINTOSC 
source)
D038
2.2
3.0
mA
-40°C to +125°C
V
DD
 = 3.0V
D039
2.5
3.5
mA
-40°C to +125°C
V
DD
 = 5.0V
D041
6.2
8.5
mA
-40°C to +125°C
V
DD
 = 3.0V
F
OSC
 = 64 MHz
(RC_RUN mode, 
HFINTOSC + PLL 
source)
D043
6.2
8.5
mA
-40°C to +125°C
V
DD
 = 3.0V
F
OSC
 = 64 MHz
(RC_RUN mode, 
HFINTOSC + PLL 
source)
D044
6.8
9.5
mA
-40°C to +125°C
V
DD
 = 5.0V
27.3
DC Characteristics: RC Run Supply Current, PIC18(L)F2X/4XK22 (Continued)
 PIC18LF2X/4XK22
Standard Operating Conditions (unless otherwise stated)
Operating temperature
-40°C 
 T
A
 
 +125°C
 PIC18F2X/4XK22
Standard Operating Conditions (unless otherwise stated)
Operating temperature
-40°C 
 T
A
 
 +125°C
Param 
No.
Device Characteristics
Typ
Max
Units
Conditions
Note
1:
The supply current is mainly a function of operating voltage, frequency and mode. Other factors, such as I/O pin loading 
and switching rate, oscillator type and circuit, internal code execution pattern and temperature, also have an impact on 
the current consumption.
Test condition: All Peripheral Module Control bits in PMD0, PMD1 and PMD2 set to ‘1’. 
2:
The test conditions for all I
DD
 measurements in active operation mode are: 
All I/O pins set as outputs driven to Vss;
MCLR = V
DD
;
OSC1 = external square wave, from rail-to-rail (PRI_RUN and PRI_IDLE only).