Emmerich 250H 2.4V NiMH Button Cell Battery Pack, Rechargeable, Tagged, 251531 Data Sheet
Product codes
251531
5.2 TEST METHOD & PERFORMANCE
Test Unit
Specification Conditions Remarks
Capacity mAh
≥280
Standard
Charge/discharge
Up to 3 cycles
Are allowed
Open Circuit
Voltage (OCV)
Voltage
(V)
≥2.6
After 1 hour standard
Charge
Internal
Impedance
mΩ/cell
≤800
Upon fully charge
(1KHz)
High rate
Discharge(140 mA)
Minute
≥60
Standard charge
Before discharge
Discharge
Current
mA 140
Maximum continuous
Discharge current
Over charge
No leakage
Not explosion
8.4mA charge
one year
Charge
Retention
mAh 224
Standard charge;
Storage: 28 days;
Standard discharge
Cycle Life
Cycle
≥400 IEC/CEI61951-2:2001.
4.4
Leakage
No
leakage
nor
Deformation
Fully charge at 28mA,
Stand 14 days
Note 2 IEC/CEI61951-2:2001. 4.4 cycle life
Cycle number
Charge
Stand in charged Condition
Discharge
1
28mA for 16h
None
70mA for 2h20min
2-48
70mA for 3h10min
None
70mA for 2h20min
49
70mA for 3h10min
None
70mA to 1.0V/cell
50
28mA for 16h
1h to 4h
56mA to 1.0V/cell
1. Befor the endurance in cycles test, the cell shall be discharged at 56mA to a final voltage of
1.0V/cell.
2.The following endurance test shall then be carried out, in an ambient temperature of 20℃±5℃.
5.3 Humidity
The battery shall not leak during the 14 days which it is submitted to the condition
of a temperature of 33±3℃ and a relative humidity of 80±5%.
6.
OTHERS
6.1 We recommend you to set the cut-off voltage at 1.0V/cell.
6.2 If the cut-off voltage is above 1.1V/cell, the battery may be underutilized resulting
insufficient use of the available capacity.
6.3 If it is below 1.0V/cell the battery may have discharge or reverse charge to the cell.