Emmerich 250H 2.4V NiMH Button Cell Battery Pack, Rechargeable, Tagged, 251531 Data Sheet

Product codes
251531
Page of 4
 
5.2  TEST METHOD & PERFORMANCE 
 
Test Unit 
Specification Conditions  Remarks 
Capacity mAh 
≥280 
Standard 
Charge/discharge 
Up to 3 cycles 
Are allowed 
Open Circuit 
Voltage (OCV) 
Voltage 
(V) 
≥2.6 
After 1 hour standard 
Charge 
 
Internal 
Impedance 
mΩ/cell 
≤800 
Upon fully charge 
(1KHz) 
 
High rate 
Discharge(140 mA) 
Minute 
≥60 
Standard charge 
Before discharge 
 
Discharge 
Current 
mA 140 
Maximum continuous 
Discharge current 
 
Over charge 
 
No leakage 
Not explosion 
8.4mA charge 
one year 
 
Charge 
Retention 
mAh 224 
Standard charge; 
Storage: 28 days; 
Standard discharge 
 
Cycle Life 
Cycle 
≥400 IEC/CEI61951-2:2001. 
4.4 
 
Leakage 
 No 
leakage 
nor 
Deformation 
Fully charge at 28mA, 
Stand 14 days 
 
 
Note 2 IEC/CEI61951-2:2001. 4.4 cycle life 
Cycle number 
Charge 
Stand in charged Condition
Discharge 
28mA for 16h 
None   
70mA for 2h20min 
2-48 
70mA for 3h10min 
None 
70mA for 2h20min 
49 
70mA for 3h10min 
None 
70mA to 1.0V/cell 
50 
28mA for 16h 
1h to 4h 
56mA to 1.0V/cell 
1. Befor the endurance in cycles test, the cell shall be discharged at 56mA to a final voltage of 
1.0V/cell. 
2.The following endurance test shall then be carried out, in an ambient temperature of 20℃±5℃. 
 
 
5.3 Humidity 
The battery shall not leak during the 14 days which it is submitted to the condition   
of a temperature of 33±3℃  and a relative humidity of 80±5%. 
 
6. 
OTHERS 
6.1  We recommend you to set the cut-off voltage at 1.0V/cell. 
6.2  If the cut-off voltage is above 1.1V/cell, the battery may be underutilized resulting 
    insufficient use of the available capacity. 
6.3  If it is below 1.0V/cell the battery may have discharge or reverse charge to the cell.