SYMBOLS USED IN THIS MANUAL
INTRODUCTION
SCOPE OF USE
FEATURES
Important: Read these instructions carefully so as to familiarise yourself with the appliance before 
connecting it to its gas cartridge. Keep these instructions for future reference. Give these instructions 
to any third person using the appliance.
This appliance is designed for heating. It is not intended for indoor use and it may only be used 
outside. Use of the product for any other purpose and / or modification of the product count as 
misuse, can be highly dangerous and is forbidden.
1.  
Gas cartridge compartment
1a.   Door
2.  
Appliance valve
2a.   Seal
3.  
Handle
4.  
Control knob
 
 
= OFF
 
 
= Pilot flame, Piezo ignition
 
 
= Low setting
 
 
= High setting
5.  
Ceramic plate
6.  
Spark of Piezo iginition
7.  
Sensor of flame supervision device
8.  
Pilot flame, oxygen depletion sensor
9.  
Grille
10.    Rothenberger “Multigas 300” butane-
propane gas cartridge (not included in 
scope of delivery)
10a.   Threaded valve
=    Caution,  
hot parts
=    Use  
outdoors  
only
=    Read the operating 
instructions
=    Keep out  
of reach  
of children
TECHNICAL SPECIFICATIONS – ROTEMP M 2000
Appliance category / type of gas: 
Direct pressure butane-propane mixture
Gas container: 
This appliance shall only be used with a Rothenberger 
“Multigas 300” butane-propane non-refillable gas 
cartridge. It may be hazardous to attempt to fit other 
types of gas containers.
Heat input: 
1.6 kW / 112 g/h
Injector diameter: 
0.75 mm
 Safety features:
Flame supervision device, oxygen depletion sensor, tilt 
switch
0359
USE OUTDOORS ONLY
GAS
PIEZO