Horizon FCJJ-23 User Manual

Page of 3
Enabling DC powered operation
Open  the  battery  compartment  located 
underneath the refueling station by sliding 
the cover according to the arrow.
Connect  the  refueling  station’s  output 
valve  to  the  car’s  input  valve  turning 
clockwise while gently pressing in. 
Creating renewable hydrogen 
solar power
AA BA
TTER
Y
AA BA
TTER
Y
Distilled water
Slowly  pour  water  into  the  water  tank 
opening above the refueling station until the 
water level reaches the top. Let the water 
rest in the tank for at least 5 minutes before 
moving on to the next step. This allows the 
electrolyzer time to absorb the water.
TIP: For optimal 
operation and 
longer life of the 
refueling station, 
use of distilled 
water is highly 
recommended. 
You can 
purchase distilled 
water from your 
local drugstore or 
pharmacy.
 
DC
off
Switch the refueling station to the "☼" sign. 
The small blue lights will now be flashing and 
you are now producing hydrogen fuel using 
unlimited  power  from  the  sun! You  can  see 
you  are  producing  hydrogen  when  small 
oxygen bubbles form on the right side of the 
water  tank.  Turn  the  switch  off  and  the 
hydrogen production will stop. 
To  purge  the  complete  fuel  cell  power 
system,  remove  all  the  air  out  of  the 
balloon by pulling on the syringe. Stop 
pulling on the syringe once all the air is 
removed from the balloon. 
Refueling and operation
Push all the air out of the syringe. Insert 
the gas purging syringe into the car’s input 
valve turning the syringe’s connector valve 
clockwise while gently pressing in.
Tips: 
1. Use the first tank of hydrogen to purge out impure gas
-- Fill the hydrogen tank and press the purging valve to 
release hydrogen completely.
2. Use the second tank of hydrogen to warm up the fuel cell
-- Re-fill the hydrogen tank and warm up the fuel cell with 
this 2nd tank of hydrogen until the balloon is empty. 
3. Run the car with the 3rd tank of Hydrogen
-- Re-fill the hydrogen tank and it’s time to run the car. 
Enjoy!
Attach the back of the solar panel to its small rectangular 
support  provided  in  the  kit.  You  can  decide  to  place  the 
solar panel vertically or horizontally depending on how you 
position the support on the back of the panel. Connect the 
black cable to the black input jack on the solar cell, and the 
red cable to the red input jack on the solar cell.
Connect the other end of the cable to the input jack of the 
refueling station. 
Place the solar panel in direct sunlight.
WARNING: Make sure these connections are 
correct. If connected incorrectly the refueling 
station may not function properly.
If  it  is  getting  dark,  or  if 
the  sun  is  not  very 
powerful, or if you want to 
accelerate refueling time, 
you  can  at  any  time 
switch 
the 
refueling 
station  to  "DC".  In  this 
case  hydrogen  would  be 
produced 
using 
the 
power of two AA alkaline 
batteries (step 7).
Disconnect  the  syringe  connector  valve  from  the 
additional input valve attached to the refueling station 
by turning it counterclockwise, allowing the connector 
to  pop  out.  Your  storage  tank  is  now  purged  and 
ready to receive hydrogen from the refueling station.
TIP: After 20 minutes of continuous use, turn the Hydrogen 
Station off, and let it rest for at least 10 minutes before 
starting it again.
Using  the  solar  panel,  make  sure  it  is  placed  in 
direct sunlight. It will take about 10 minutes in strong 
sunlight  for  the  car's  tank  to  fill  up  with  hydrogen 
using the standard solar panel included. Keep the 
refueling station powered until the balloon inside the 
hydrogen storage cylinder is full. Once the operation 
is complete and the balloon is full, make sure you 
turn the refueling station to the "off" position.
Alternative: It will take at least 1 minute for the 
balloon to fill with hydrogen using the "DC" power 
switch if the batteries are new.
WARNING: Continuous operation 
of the Hydrogen Station could 
damage it permanently.
Remote control
Step 1: Use the screwdriver to open the 
cover of the battery compartment.
Step 2: Insert 3 new LR44 batteries with 
the correct polarity positions.
Step 3: Use the screwdriver to close the 
cover of the battery compartment.
Activation of fuel cell 
and operation
Press  the  buttons  on 
the  remote  control  to 
control  forward  and 
backward  motions  of 
the car. Press the right 
button to keep the car 
moving forward. Press 
the  button  located  in 
the middle to keep the 
car moving backward. 
The car can turn when 
it moves backwards. If 
the car runs slowly or 
cannot run with a fully 
charged balloon, refer 
to the following step. 
Turn the switch to “warm up” position. Leave the car until it 
fully  consumes  the  hydrogen  and  activates  the  fuel  cell. 
Turn  the  switch  to  the  “off”  position.  Repeat  refueling 
process again to fill storage container with hydrogen.
It is estimated that on a full tank and after “warm up” the 
H-racer  2.0  will  run  up  to  several  minutes.  Once  the 
operation is complete and the balloon is full, make sure you 
turn the hydrogen station to the “off” position. 
ON OFF WARM
 
UP
Place  two  1.5V  AA  alkaline  batteries  inside  the 
battery  compartment  as  indicated,  then  close  the 
battery compartment.
 Direction adjuster
To adjust the car’s movement and 
direction,  or  if  the  car  doesn’t 
straight,  turn  the  adjuster  on  the 
bottom of the chassis slightly to the 
left  or  right  until  the  desired 
direction is achieved. 
Make sure the switch beneath the car's chassis is at 
the "off" position.