Freescale Semiconductor Xtrinsic MAG3110 Magnetometer RD4247MAG3110 RD4247MAG3110 User Manual

Product codes
RD4247MAG3110
Page of 22
RD4247MAG3110 Sensor Toolbox Tilt-Compensated eCompass Kit User’s Guide, Rev. 2
16
Freescale Semiconductor
 
Advanced eCompass Features
The fitted geomagnetic field strength in µT.
Geomagnetic field B (uT)
52.31701
The calibration Fit Error in %.
Calibration fit error %
0.7030118
The number of measurement equations used for this calibration.
Measurements used in solution
49
The sample number index of the earliest magnetometer reading used for the calibration.
Earliest sample index used
-1
The number of measurements stored in the Smart FIFO.
Smart FIFO count
49
The actual magnetometer measurements stored in the Smart FIFO.
Sample index
Bpx (uT)
Bpy (uT)
Bpz (uT)
80
304.5
16.9
-37.6
13
245.7
-6.4
-33.8
92
298.3
15.5
-73.2
93
300.2
13.6
-66
78
299
21
-23.1
...68
219.9
42.1