Voltcraft AT-200 Digital-Multimeter, DMM, 4000 counts AT-205P Data Sheet

Product codes
AT-205P
Page of 62
39
Technical Data and Measurement 
Tolerances
Technical data
Display
:  3 
3
/
4
-digit LCD 
Speed of measurement
:  2 measurements / sec.
Input resistance
:  approx. 10M
Ω
Battery replacement symbol
:  <7.5V +/- 0,5V
Acoustic signal
:  for each button activation
Battery required
:  9V compound battery, NEDA 1604 or 006P type
Operating temperature
:  0°C to 50°C
Storage temperature
:  -20°C to 60°C
Rel. air humidity
:  < 70% (non-condensing)
Operating height
:  up to a max. 2,000 m above MSL
Temp. for guaranteed accuracy
:  +18°C to +28°C
Weight (incl. battery)
:  approx. 220 g
Dimensions (LxWxH)
:  146 x 66 x 41 (mm)
Measurement tolerances
Statement of accuracy in ± (% of reading (= reading = rdg) + display error in digits 
(= dgt = no. of the smallest points)). The accuracy is valid for 1 year at a temperature
of +23°C +/5°C, and at a relative humidity of less than 75 %, non-condensing.
Type of operation
Measuring range
Accuracy
Resolution
DC volt
400mV
+/-(0.8%+3dgt)
0.1 mV
4 V
+/-(1.5%+3dgt)
0.001 V
40 V
+/-(1.5%+3dgt)
0.01 V
400 V
+/-(1.5%+3dgt)
0.1 V
600 V
+/-(2.0%+5dgt)
1 V
Overload protection: 600 V; input resistance: 10 M
Ω
AC volt
400 mV
+/-(1,8%+40dgt)
0.1 mV
4 V
+/-(1.3%+3dgt)
0.001 V
40 V
+/-(1.8%+3dgt)
0.01 V
400 V
+/-(1.8%+3dgt)
0.1 V
600 V
+/-(2.5%+6dgt)
1 V
Overload protection: 600 V; input resistance: 10 M
Ω
No auto range in the 400mV range
Frequency of the alternating voltage: 50 Hz to 400 Hz
DC ampere
400 µA
+/-(1.0%+3dgt)
0.1 µA
4000 µA
+/-(1.5%+3dgt)
1 µA
40 mA
+/-(1.5%+3dgt)
0.01 mA