REPLACING THE FUSES
WARNING: To avoid electrical shock, disconnect the meter from any circuit, remove the
test leads from the input terminals, and turn OFF the meter before opening the case. Do
not operate the meter with an open case.
test leads from the input terminals, and turn OFF the meter before opening the case. Do
not operate the meter with an open case.
1. Disconnect the test leads from the meter.
2. Remove the protective rubber holster.
3. Remove the battery cover (two “B”
2. Remove the protective rubber holster.
3. Remove the battery cover (two “B”
screws) and the battery.
4. Remove the four “A” screws securing the
rear cover.
5. Lift the center circuit board straight up
from the connectors to gain access to the
fuse holders.
fuse holders.
6. Gently remove the old fuse and install the
new fuse into the holder.
7. Always use a fuse of the proper size and
value (0.5A/250V fast blow for the 400mA
range, 20A/250V fast blow for the 20A
range).
range, 20A/250V fast blow for the 20A
range).
8. Align the center board with the connectors and gently press into place.
9. Replace and secure the rear cover, battery and battery cover.
9. Replace and secure the rear cover, battery and battery cover.
WARNING: To avoid electric shock, do not operate your meter until the fuse cover is in
place and fastened securely.
place and fastened securely.