•   Be especially careful when dealing with voltages higher than 33 V/AC or 70 V/DC.
Even at such voltages you can get a life-threatening electric shock if you come
into contact with live electric wires.
•   Always connect the testing leads first to the meter before connecting the leads to
the test object.
•   When using the crocodile clips, ensure that the various cables, wires or electronic
components won’t get crimped or even damaged.
•   The measuring unit is only suitable for use in a dry environment.
Avoid using the
device in a damp or wet environment.
•   Always ensure that the testing clips are perfectly clean. Dirty or corroded test clips
can give an erroneous reading.
•   Make sure always that the crocodile clips are seated on clean leads or contacts.
If the required strength of the clips is no longer satisfactory, replace with new clips
of identical type.
•   Do not exceed the maximum permissible voltage values. Exceeding the specified
values will result in damage to the product and poses a danger to life. (See
chapter Technical data.)
•   Stow your meter including accessories safely in the carrying bag as soon as it is
no longer needed.
deScripTion oF SymbolS
Risk of electric shock
Warning
Tools and test devices to be connected to hazardous live conductors. Personal
protective equipment is recommended.
Protection class 2 (double or reinforced insulation)
Earth potential
The device is CE-conform and complies with the applicable national and
European directives.
cAT iV
Measurement category CAT IV 600 V for measurements at the source of low
voltage installations, according to EN 61010-1
oFF
The matching indicator is not active
on
The matching indicator is active
l1 (A)
phase 1
l2 (b)
phase 2
l3 (c)
phase 3
l1 missing  phase 1 not present on the measured object
l2 missing  phase 2 not present on the measured object
l3 missing  phase 3 not present on the measured object
Rotate Right (clockwise turned field)
Rotate Left (counter-clockwise turned field)
conTrolS  
 
 
1 Phase indicator L1, L2, L3
2 Clockwise rotary field indicator
3 Counter-clockwise rotary field indicator
4 LCD display
5 Test leads
6 Connection for test leads
G
 operATing inSTrucTionS
phASe roTATion TeSTer “Vc35”
iTem no. 1017868
inTended uSe
The phase sequence tester serves as a meter and testing device indicating the phase
sequence or direction of rotation in a three-phase network in the range of the measurement
category for phase rotation in accordance with EN 61010, and all lower categories. The meter
also shows whether all 3 phases are available.
The meter’s voltage is supplied only via the phases of the test
object that are connected to it. No batteries or rechargeable batteries are required.
Measuring under adverse ambient conditions such as dust and flammable gases, vapours or
solvents is not permitted.
Always observe the safety instructions and all other information included in these operating
instructions.
This product satisfies the applicable national and European requirements. All company and/or
product names are the trademarks of their respective owners. All rights reserved.
conTenTS
•  Phase rotation tester
•  3 test leads
•  3 Crocodile clips
•  Carrying bag
•  Operating instructions
explAnATion oF The SymbolS
  An exclamation mark inside a triangle refers to important. notes in the operating
instructions.
  The lightening flash symbol in a triangle warns against the risk of an electric shock
or interference with the electrical safety of the device.
SAFeTy inSTrucTionS
The warranty will expire in case of any damage caused by the failure to follow 
these operating instructions! we assume no liability for any resulting conse-
quential damage!
 
 we assume no liability for any damage to property or personal injuries 
caused by improper use or non-compliance with the safety instructions! in 
such cases, the warranty will be null and void.
•   The unauthorised conversion and/or modification of the product is not permitted
for safety and approval reasons (CE). Never disassemble the product.
•   The product is not a toy. Therefore, be especially careful when children are
around.
 Use the product where it is out of the reach of children.
•   Never use the product immediately after taking it from a cold room to a warm one.
The condensation that forms may destroy the product.
•   Avoid the following adverse conditions at the installation location and during
transport:
-  Extreme cold or heat, direct sunlight
-  Dust or flammable gases, fumes or solvents
-  Strong impacts, blows
•   Do not leave packaging material carelessly lying around, since it could become a
dangerous plaything for children.
•   Handle the product with care; impacts; blows, or accidental falls, even from a low
height can damage it.
•   Only hold the terminals by their hand grips. Never reach across the tangible
markings of the grip area and do not touch any live parts. Protective equipment is
recommended.
•   Prior to each measurement, check your instrument and the measuring leads for
damages. Never take any measurements if the protecting insulation is defective.
VerSion 08/14