36 
To set the IR-Fusion
 
 mode: 
1.  Push . 
2.  Push / to highlight Measurement
3.  Push  or  to view the menu. 
4.  Push / to highlight Image
5.  Push  or  to view the menu. 
6.  Push / to highlight IR-Fusion
7.  Push  or  to view the menu. 
8.  Push / to highlight an option. 
9.  Push: 
•   to set the change and go back to the live view. 
•   or  to set the change and go back to the previous menu. 
•   to cancel the change and go back to the live view. 
Color Alarm 
Applies to: Ti110, Ti125, TiR110, TiR125 
The Imager has various apparent temperature color alarms. The high-
temperature color alarm shows a full visible image and only shows infrared 
information on objects or areas that are above the set apparent temperature 
alarm level. The low-temperature/dew point color alarm shows a full visible 
image and only shows infrared information on objects or areas that are below 
the set apparent temperature/dew point color alarm level. The user must 
manually find and set these parameters. The imager also displays color 
isotherms, or infrared information, inside or outside of a set of both high and 
low limits.