The thermal imager camera can measure from -20~250°C (-4~482°F) and displays the thermal image and temperature. 
Furthermore, thermal images can be saved to a micro SD card. Transferring images to the software is included for image report 
generation from these saved images.
 
 
OPERATION 
1.
 
Power on 
Press Mode Key (○,
2
) or Trigger (○,
10
) to power on the unit. 
2.
 
Taking a thermal image and temperature 
After power on, simply aim the thermal imager camera at the measure target with Lens 
(○,
9
)  and  get  the  thermal  image  and  temperature  immediately.  Please  make  sure  the 
target area is within the field of view. 
Note: There are three cursors on the screen. The cross sign shows the temperature of 
the  object  located  in  the  middle  of  the  screen.  Other  two  moving  cursors  indicate  the 
highest and lowest temperatures in the thermal image. 
3.
 
Save thermal images 
Press  Trigger  (○,
10
)  to  save  the  thermal  image  to  the  micro  SD  card,  press  Up  Key 
(○,
3
)  or  Down  Key  (○,
4
)  to  show the  saved  images.  Press Mode  Key  (○,
2
)  again  to 
return to the measurement screen.
 
4.
 
Color palettes 
Press Color Palette Key (○,
6
) to select the color palette (4 selectable color palettes) to view thermal images. 
 
 
 
 
Ironbow 
Rainbow 
High contrast 
Grayscale 
5.
 
°C/°F/K 
Press Unit Key (○,
5
) for  °C、°F or K transferred. 
6.
 
Power off 
        Press Mode Key (○,
2
) for more than 5 sec. to power off the unit. Auto power off time is around 30 sec..
 
 
FUNCTIONS 
Press  Mode  Key  (
,
2
)  for  scrolling  more  display  functions,  then  press  Up  key (
,
3
)  or  Down  key  (
,
4
)  to  change  the 
functions, then press Trigger (
,
10
) to confirm it. 
Emissivity 
The default emissivity is 0.95, or select other default emissivity: Matt:0.95Semi-matt:0.8Semi-glossy:0.6
Glossy:0.3 
Select Set value to adjust the emissivity (0.1 to 1 step .01). 
HAL 
You  can  select  Set  Min  temp  or  Set  Max  item  to  adjust  the  High  Alarm  (HAL)  or  Lo  Alarm  (LAL)  limits 
(step .1). 
LAL 
Language 
Selectable Chinese or English
Backlight 
Selectable 5 levels of brightness. 
Set Time 
Set the date and time in MM/DD/YYYY (month/day/year) and HH/MM/SS (hour/minute/second) formats. 
Time stamp 
Turn on Time stamp to save thermal images with real-time stamp.   
Turn off Time stamp to hide date and time on stored thermal images. 
Erase Image 
Select Yes, All image! to clear all stored thermal images. 
Reset 
Select Reset to recover the factory setting data. 
Set parameter 
Select Use Median Value
 
to reduce noise in an image. 
Select No Filter
 
to display real image noise. 
 
STORAGE & CLEANING       
It should be stored at room temperature. The sensor lens is the most delicate part of the thermometer. The lens should be kept 
clean at all times, care should be taken when cleaning the lens using only a soft cloth or cotton swab with water or medical alcohol. 
Allowing the lens to fully dry before using the thermometer. Do not submerge any part of the thermometer.   
 
BATTERIES
 
The thermometer incorporates visual low battery indication as follows: 
 
 
 
‘Battery OK’: measurements 
  are possible 
‘Battery Low’: battery needs to be   
replaced, measurements are still possible 
‘Battery Exhausted’: measurements are 
not possible 
  When the ‘Low Battery’ icon indicates the battery is low, the battery should be replaced immediately with AA, 1.5V batteries. 
Please note: It is important to turn the instrument off before replacing the battery otherwise the thermometer may malfunction. 
  Dispose of used battery promptly and keep away from children. 
 
SPECIFICATION 
Thermal Image Resolution 
32*31 
Measurement Range 
-20~250°C (-4~482°F) 
Accuracy (Tamb=20~26°C) 
±2% of reading, or 2°C(4°F) whichever is greater 
Thermal Sensitivity 
0.1°C 
Frame Rate 
9Hz 
Field of View 
40*40 deg 
Emissivity Range 
0.95 default – adjustable 0.1 to 1 step .01 
Focus 
Focus free 
LCD (inch) 
2.8 
LCD Type 
Color 
Image Storage 
Stores up to 60000 images/GB, 
Bitmap (BMP) file format.
 
Memory Type 
Support 8G micro SD card 
Sensor Filter (um) 
8~14um 
Interface 
USB 
Battery Type 
AA*4 
Battery Life (hr)(backlit) 
6   
Dimensions 
94.65 x 74.03 x 233.68mm (3.73 x 2.91 x 9.20 inch) 
Weight 
411 grams(14.5 oz) including batteries (AA*4pcs) 
 
EMC/RFI: Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of approximately 3 volts per 
meter, but the performance of the instrument will not be permanently affected.
 
* IP54 Splash Proof