The thermal imager camera can measure from -20~250°C (-4~482°F) and displays the thermal image and temperature.
Furthermore, thermal images can be saved to a micro SD card. Transferring images to the software is included for image report
generation from these saved images.
Furthermore, thermal images can be saved to a micro SD card. Transferring images to the software is included for image report
generation from these saved images.
OPERATION
1.
Power on
Press Mode Key (○,
Press Mode Key (○,
2
) or Trigger (○,
10
) to power on the unit.
2.
Taking a thermal image and temperature
After power on, simply aim the thermal imager camera at the measure target with Lens
(○,
After power on, simply aim the thermal imager camera at the measure target with Lens
(○,
9
) and get the thermal image and temperature immediately. Please make sure the
target area is within the field of view.
Note: There are three cursors on the screen. The cross sign shows the temperature of
the object located in the middle of the screen. Other two moving cursors indicate the
highest and lowest temperatures in the thermal image.
Note: There are three cursors on the screen. The cross sign shows the temperature of
the object located in the middle of the screen. Other two moving cursors indicate the
highest and lowest temperatures in the thermal image.
3.
Save thermal images
Press Trigger (○,
Press Trigger (○,
10
) to save the thermal image to the micro SD card, press Up Key
(○,
3
) or Down Key (○,
4
) to show the saved images. Press Mode Key (○,
2
) again to
return to the measurement screen.
4.
Color palettes
Press Color Palette Key (○,
Press Color Palette Key (○,
6
) to select the color palette (4 selectable color palettes) to view thermal images.
Ironbow
Rainbow
High contrast
Grayscale
5.
°C/°F/K
Press Unit Key (○,
Press Unit Key (○,
5
) for °C、°F or K transferred.
6.
Power off
Press Mode Key (○,
2
) for more than 5 sec. to power off the unit. Auto power off time is around 30 sec..
FUNCTIONS
Press Mode Key (
○,
2
) for scrolling more display functions, then press Up key (
○,
3
) or Down key (
○,
4
) to change the
functions, then press Trigger (
○,
10
) to confirm it.
Emissivity
The default emissivity is 0.95, or select other default emissivity: Matt:0.95, Semi-matt:0.8, Semi-glossy:0.6,
Glossy:0.3
Select Set value to adjust the emissivity (0.1 to 1 step .01).
Glossy:0.3
Select Set value to adjust the emissivity (0.1 to 1 step .01).
HAL
You can select Set Min temp or Set Max item to adjust the High Alarm (HAL) or Lo Alarm (LAL) limits
(step .1).
(step .1).
LAL
Language
Selectable Chinese or English.
Backlight
Selectable 5 levels of brightness.
Set Time
Set the date and time in MM/DD/YYYY (month/day/year) and HH/MM/SS (hour/minute/second) formats.
Time stamp
Turn on Time stamp to save thermal images with real-time stamp.
Turn off Time stamp to hide date and time on stored thermal images.
Turn off Time stamp to hide date and time on stored thermal images.
Erase Image
Select Yes, All image! to clear all stored thermal images.
Reset
Select Reset to recover the factory setting data.
Set parameter
Select Use Median Value
to reduce noise in an image.
Select No Filter
to display real image noise.
STORAGE & CLEANING
It should be stored at room temperature. The sensor lens is the most delicate part of the thermometer. The lens should be kept
clean at all times, care should be taken when cleaning the lens using only a soft cloth or cotton swab with water or medical alcohol.
Allowing the lens to fully dry before using the thermometer. Do not submerge any part of the thermometer.
clean at all times, care should be taken when cleaning the lens using only a soft cloth or cotton swab with water or medical alcohol.
Allowing the lens to fully dry before using the thermometer. Do not submerge any part of the thermometer.
BATTERIES
The thermometer incorporates visual low battery indication as follows:
‘Battery OK’: measurements
are possible
‘Battery Low’: battery needs to be
replaced, measurements are still possible
‘Battery Exhausted’: measurements are
not possible
When the ‘Low Battery’ icon indicates the battery is low, the battery should be replaced immediately with AA, 1.5V batteries.
Please note: It is important to turn the instrument off before replacing the battery otherwise the thermometer may malfunction.
Dispose of used battery promptly and keep away from children.
SPECIFICATION
Thermal Image Resolution
32*31
Measurement Range
-20~250°C (-4~482°F)
Accuracy (Tamb=20~26°C)
±2% of reading, or 2°C(4°F) whichever is greater
Thermal Sensitivity
0.1°C
Frame Rate
9Hz
Field of View
40*40 deg
Emissivity Range
0.95 default – adjustable 0.1 to 1 step .01
Focus
Focus free
LCD (inch)
2.8
LCD Type
Color
Image Storage
Stores up to 60000 images/GB,
Bitmap (BMP) file format.
Memory Type
Support 8G micro SD card
Sensor Filter (um)
8~14um
Interface
USB
Battery Type
AA*4
Battery Life (hr)(backlit)
6
Dimensions
94.65 x 74.03 x 233.68mm (3.73 x 2.91 x 9.20 inch)
Weight
411 grams(14.5 oz) including batteries (AA*4pcs)
EMC/RFI: Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of approximately 3 volts per
meter, but the performance of the instrument will not be permanently affected.
* IP54 Splash Proof