Fluke Ti100 , 9 Hz thermography camera, -20 to +250 °C, 160 x 120 pix bolometer matrix 3810290 User Manual

Product codes
3810290
Page of 56
 Thermal 
Imagers 
 
Menus 
 27 
Center Box 
The Center Box feature is an adjustable temperature measurement zone (box) 
that you can center on the infrared image. This zone (box) expands and 
contracts to different levels in the infrared image. The zone lets the user see an 
approximate maximum (MAX), average (AVG), and minimum (MIN) 
temperature measurement in that area. 
Note 
When the Center Box feature is on, the HI/LO Spot Temperature 
markers do not function. The Adjustable Fixed Temperature Spots only 
function within the selected Center Box area. The level and span of the 
Imager is also adjusted to the thermal scene within the Center Box.
 
To enable or disable the Center Box feature: 
1.  Push . 
2.  Push / to highlight Measurement
3.  Push  or  to view the menu. 
4.  Push / to highlight Center Box
5.  Push  or  to view the menu. 
6.  Push / to toggle the function ON or OFF
To set the size of the Center Box when enabled: 
1.  Push / to highlight Set Size
2.  Push  or  to view the display. 
3.  Push  to increase the size of the Center Box
4.  Push  to reduce the size of the Center Box
5.  When satisfied with the size of the Center Box, push: 
   or  to set the change and go back to the previous menu. 
   to cancel the change and go back to the live view.