Keysight Technologies USB data capturing module 2541A Input: 250 kS/s, output: 1 MS/s U2541A OPT 902 + ABD User Manual

Product codes
U2541A OPT 902 + ABD
Page of 5
3
In this application, the program is written in Agilent VEE Pro to control the DAQ 
devices in acquiring the voltage and current as shown in Figure 3.
Figure 3. Windows shown is the VEE test program.
The functionality of the PMU is controlled by its fi rmware. In this particular 
application, the VEE program is used to control the DAQ devices with regard 
to the monitoring of the different channels. In addition, a separate routine is 
written to run through the functionality of the PMU. Alternatively, another 
routine can be written to control the DAQ and the fi rmware together and to 
easily establish a correlation between the DAQ results and the functionality. 
During channel monitoring in this particular application a glitch is detected in 
one of the channels, as shown in Figure 4.
Figure 4. The graph shows an actual glitch detected by the DAQ.