Nortel Business Communications Manager 200, 24 User, IP Personal Productivity Suite NTE803BA User Manual
Product codes
NTE803BA
Technical Bulletin
Nortel Business Communications Manager 200 and
Business Communications Manager 400
Business Communications Manager 400
Technical Specifications
Base unit
Physical dimensions
BCM400
BCM200
Depth
18.3 in.; 46.5 cm
18.3 in.; 46.5 cm
Width
17.5 in.; 44.5 cm
17.5 in.; 44.5 cm
Height
7.1 in.; 18.0 cm
3.5 in.; 9.0 cm
Weight
Std. 35.2 lbs;
Std. 24.9 lbs;
15.9 Kg
11.3 Kg
Redundant 46.7 lbs;
21.2 Kg
21.2 Kg
Components BCM400
BCM200
Media Bay Module Bays
Four Two
CPU Processor
Intel Celeron 1.2 GHz Intel Celeron 1.2 GHz
Memory (RAM)
256 MB SDRAM
256 MB SDRAM
Hard Drive
20 GB EIDE
20 GB EIDE
System Status LEDs
Power status, Hard drive activity, System status, PCI device monitoring
(MSC, WAN, NIC 1, NIC 2), Chassis/CPU temperature, Fan activity
reset button
The System Status Monitor Card controls and monitors fans, power
supply, chassis temperature and OS status.
(MSC, WAN, NIC 1, NIC 2), Chassis/CPU temperature, Fan activity
reset button
The System Status Monitor Card controls and monitors fans, power
supply, chassis temperature and OS status.
Mounting options
Rack-mount (standard 19-inch rack); Stand-alone (feet included); Wall-
mount (optional wall-mount bracket available separately)
mount (optional wall-mount bracket available separately)
Power supply specifications
Standard power supply
Redundant power supply (BCM400 only)
Auto-sensing Auto-sensing
300 Watts
300 Watts
350 Watts
90/264 VAC
90/264 VAC
6.0 A/3.0 A
7.0 A/3.5 A
60/50 Hz
60/50 Hz
Environmental specifications
Operating temperature
32º to 104ºF; 0º to 40ºC
Operating humidity
10% to 90% relative humidity,
non-condensing
non-condensing
Storage temperature
-67º to 158ºF; -55º to 70ºC
Storage humidity
Up to 95% relative humidity
Mechanical requirements
NEBS (GR-63-CORE) compliant for Transportation and Operational
Vibration per IEC 68-2-27, Package Drop Shock resistance per ISTA 1A
Transportation Bounce to IEC 68-2-55 and Unpackaged Drop to ISTA
Project 1A
Vibration per IEC 68-2-27, Package Drop Shock resistance per ISTA 1A
Transportation Bounce to IEC 68-2-55 and Unpackaged Drop to ISTA
Project 1A
Regulatory compliance
Electromagnetic emissions
Radiated Air
Australia AS3548 Class A
North America CISPR22 Class A
United Kingdom EN55022 Class A
North America CISPR22 Class A
United Kingdom EN55022 Class A
Conducted Power Leads Australia AS3548 Class A
North America CISPR22 Class A
United Kingdom EN55022 Class A
United Kingdom EN55022 Class A
Immunity (Narrow band RF interference)
Radiated
North America customer driven
(based on EN 61000-4-3)
United Kingdom/International
EN55024 : 1998
(based on EN 61000-4-3)
United Kingdom/International
EN55024 : 1998
Conducted
North America customer driven
(Based on EN 61000-4-6)
United Kingdom/International
EN55024 : 1998
(Based on EN 61000-4-6)
United Kingdom/International
EN55024 : 1998
Immunity to electrostatic discharge
Indirect
No functional impairment up to +/- 8 kV
Direct
Mated I/O ports and connectors,
No damage up to +/- 4 kV
Mated connector and cords,
No functional impairment up to +/- 8 kV,
No damage up to +/- 15 kV
No damage up to +/- 4 kV
Mated connector and cords,
No functional impairment up to +/- 8 kV,
No damage up to +/- 15 kV