Intel 2.80 GHz BX80546KG2800EA Data Sheet

Product codes
BX80546KG2800EA
Page of 96
Intel® Xeon™ Processor with 800 MHz System Bus
Datasheet
67
6.0
 Thermal Specifications
6.1
Package Thermal Specifications
The Intel® Xeon™ processor with 800 MHz system bus requires a thermal solution to maintain 
temperatures within operating limits. Any attempt to operate the processor outside these operating 
limits may result in permanent damage to the processor and potentially other components within 
the system. As processor technology changes, thermal management becomes increasingly crucial 
when building computer systems. Maintaining the proper thermal environment is key to reliable, 
long-term system operation.
A complete solution includes both component and system level thermal management features. 
Component level thermal solutions can include active or passive heatsinks attached to the 
processor Integrated Heat Spreader (IHS). Typical system level thermal solutions may consist of 
system fans combined with ducting and venting.
For more information on designing a component level thermal solution, refer to the Intel® Xeon™ 
Processor with 800 MHz System Bus Thermal/Mechanical Design Guidelines
Note:
The boxed processor will ship with a component thermal solution. Refer to 
 for details 
on the boxed processor.
6.1.1
Thermal Specifications
To allow the optimal operation and long-term reliability of Intel processor-based systems, the 
processor must remain within the minimum and maximum case temperature (T
CASE
) specifications 
as defined by the applicable thermal profile (see 
). Thermal solutions not 
designed to provide this level of thermal capability may affect the long-term reliability of the 
processor and system. For more details on thermal solution design, please refer to the appropriate 
processor thermal/mechanical design guideline.
The Intel® Xeon™ processor with 800 MHz system bus introduces a new methodology for 
managing processor temperatures which is intended to support acoustic noise reduction through 
fan speed control and assure processor reliability. Selection of the appropriate fan speed will be 
based on the temperature reported by the processor’s Thermal Diode. If the diode temperature is 
greater than or equal to Tcontrol (see 
), then the processor case temperature must 
remain at or below the temperature as specified by the thermal profile (see 
). If the diode 
temperature is less than Tcontrol, then the case temperature is permitted to exceed the thermal 
profile, but the diode temperature must remain at or below Tcontrol. Systems that implement fan 
speed control must be designed to take these conditions into account. Systems that do not alter the 
fan speed only need to guarantee the case temperature meets the thermal profile specifications.
Intel has developed two thermal profiles, either of which can be implemented with the Intel® 
Xeon™ processor with 800 MHz system bus. Both ensure adherence to Intel reliability 
requirements. Thermal Profile A (see 
) is representative of a volumetrically 
unconstrained thermal solution (i.e. industry enabled 2U heatsink). In this scenario, it is expected 
that the Thermal Control Circuit (TCC) would only be activated for very brief periods of time 
when running the most power intensive applications. Thermal Profile B (see 
) is 
indicative of a constrained thermal environment (i.e. 1U). Because of the reduced cooling 
capability represented by this thermal solution, the probability of TCC activation and performance 
loss is increased. Additionally, usage of a thermal solution that does not meet Thermal Profile B