93 
Power Requirements 
Table 21. Library Power Requirements 
Power Requirements 
Values 
Input Voltage 
100 – 240 VAC 
Input Frequency 
50 –- 60 Hz 
Inrush Current (Cold Start) 
Less than 15 A, 115 VAC 
Less than 30 A, 230 VAC 
Power Consumption Average 
70 W 
Power Consumption Peak* 
120 W* 
* Maximum peak length, less than 10ms. 
Climatic Specifications 
Table 22. Temperature Range 
Temperature 
Operating 
Range 
+10
°
C to +35
°
 
Gradient 
10
°
C/hour 
Non-Operating 
Range 
-30
°
C to +60
°
 
Gradient 
20
°
C/hour 
 
Table 23. Humidity Range 
Humidity 
Operating 
Range 
20%Rh to 80%Rh 
 
Gradient 
10%Rh/hour 
Non-Operating 
Range 
10%Rh to 90%Rh 
 
Gradient 
20%Rh /hour 
 
Table 24. Altitude Range 
Altitude 
Operating 
Range 
-500 to 10000 ft 
Non-Operating 
Range 
-500 to 40000 ft