Belden UTP CAT5E 4PR AWG24 LSNH cable, 305m 1583ENH.01U305 Data Sheet
Product codes
1583ENH.01U305
Belden 1583ENH
Product Datasheet
P/N 46376 - Rev. 3B
P/N 46376 - Rev. 3B
Page 1 of 2
Date 29-04-2009
Cat 5 enhanced UTP FRNC
Belden Wire & Cable B.V.
All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner
• Horizontal and building backbone cable.
• Support current and future Category 5 enhanced applications, such as:
• Support current and future Category 5 enhanced applications, such as:
10 Base-T, 100 Base-T, 1000 Base-T (Gibabit Ethernet), FDDI, ATM
General standards: ISO/IEC 11801, EN 50173, TSB 36, TIA/EIA 568-A-5 (enhanced)
Future standards like: JTC1 SC25 WG3 N568 and prEN 50288-3-1
Future standards like: JTC1 SC25 WG3 N568 and prEN 50288-3-1
• Construction:
Unshielded 4 twisted pairs
• Conductor:
solid bare copper
• Conductor diameter:
AWG 24 (0,51 mm)
• Conductor insulation material:
Polyethylene (PE)
• Diameter over insulation:
0,90 mm ± 0.05 mm
• Jacket material:
FRNC (Flame retardant)
• Outer diameter:
4,70 mm ± 0.30 mm
Attenuation
Frequency
1
4
10
16
20
31.25
62.5
100
MHz
Spec. (Max.)
1)
2.1
4.3
6.6
8.2
9.2
11.8
17.1
22.0
dB/100m
Typical
2.0
4.0
6.3
8.0
9.0
11.3
16.2
20.7
dB/100m
NEXT (Near end crosstalk)
Frequency
1
4
10
16
20
31.25
62.5
100
MHz
Spec. (Min.)
1)
65.3
56.3
50.3
47.3
45.8
42.9
38.4
35.3
dB
Typical
73
64
58
55
54
51
47
44
dB
Power sum NEXT
Frequency
1
4
10
16
20
31.25
62.5
100
MHz
Spec. (Min.)
1)
62.3
53.3
47.3
44.3
42.8
39.9
35.4
32.3
dB/100m
Typical
71
62
56
53
52
49
45
42
dB/100m
Power sum ELFEXT
Frequency
1
4
10
16
20
31.25
62.5
100
MHz
Spec. (Min.)
2)
60.8
48.7
40.8
36.7
34.7
30.9
24.8
20.8
dB/100m
Typical
71
59
51
46
43
39
33
28
dB/100m
ACR
Frequency
1
4
10
16
20
31.25
62.5
100
MHz
Spec. (Min.)
1)
63
52
44
39
37
31
22
14
dB/100m
Typical
71
61
52
48
45
40
31
24
dB/100m
Power sum ACR
Frequency
1
4
10
16
20
31.25
62.5
100
MHz
Spec. (Min.)
1)
60
49
41
36
34
28
19
11
dB/100m
Typical
69
59
50
46
43
38
29
22
dB/100m
1)
: Specification values according to cable requirements of ISO/IEC 11801 category 5 enhanced
2)
: Specification values according to cable requirements of ANSI/TIA/EIA-568-A-5 (enhanced)
Standards
Construction & Dimensions
Electrical characteristics (at 20 ºC)
Application
Colour code
Pair 1
White-Blue/Blue
Pair 2
White-Orange/Orange
Pair 3 White-Green/Green
Pair 4
Pair 4
White-Brown/Brown