Belden UTP CAT5E 4PR AWG24 LSNH cable, 305m 1583ENH.01U305 Data Sheet

Product codes
1583ENH.01U305
Page of 2
Belden 1583ENH 
 
Product Datasheet 
P/N 46376 - Rev. 3B
 
Page 1 of 2
 
Date 29-04-2009
 
Cat 5 enhanced  UTP  FRNC 
 
 Belden Wire & Cable B.V. 
All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner
 
 
 
 
 
 
•  Horizontal and building backbone cable. 
•  Support current and future Category 5 enhanced applications, such as: 
10 Base-T, 100 Base-T, 1000 Base-T (Gibabit Ethernet), FDDI, ATM
 
 
 
 
General standards: ISO/IEC 11801, EN 50173, TSB 36, TIA/EIA 568-A-5 (enhanced)  
Future standards like: JTC1 SC25 WG3 N568 and prEN 50288-3-1 
 
  
 
•  Construction: 
 
 
Unshielded 4 twisted pairs 
 
•  Conductor:  
 
 
solid bare copper
 
•  Conductor diameter: 
 
AWG 24 (0,51 mm) 
•  Conductor insulation material: 
Polyethylene (PE) 
•  Diameter over insulation:   
0,90 mm ± 0.05 mm 
•  Jacket material: 
 
 
FRNC (Flame retardant)  
•  Outer diameter: 
 
 
4,70 mm ± 0.30 mm 
 
 
 
 
Attenuation 
 
 
Frequency 
10 
16 
20 
31.25 
62.5 
100 
MHz 
Spec. (Max.)
1) 
2.1 
4.3 
6.6 
8.2 
9.2 
11.8 
17.1 
22.0 
dB/100m 
Typical 
2.0 
4.0 
6.3 
8.0 
9.0 
11.3 
16.2 
20.7 
dB/100m 
 
 
 
 
NEXT (Near end crosstalk) 
 
 
 
Frequency 
10 
16 
20 
31.25 
62.5 
100 
MHz 
Spec. (Min.)
1) 
65.3 
56.3 
50.3 
47.3 
45.8 
42.9 
38.4 
35.3 
dB 
Typical 
73 
64 
58 
55 
54 
51 
47 
44 
dB 
 
 
 
Power sum NEXT 
 
 
 
Frequency 
10 
16 
20 
31.25 
62.5 
100 
MHz 
Spec. (Min.)
1) 
62.3 
53.3 
47.3 
44.3 
42.8 
39.9 
35.4 
32.3 
dB/100m 
Typical 
71 
62 
56 
53 
52 
49 
45 
42 
dB/100m 
 
 
 
Power sum ELFEXT 
 
 
 
Frequency 
10 
16 
20 
31.25 
62.5 
100 
MHz 
Spec. (Min.)
2) 
60.8 
48.7 
40.8 
36.7 
34.7 
30.9 
24.8 
20.8 
dB/100m 
Typical 
71 
59 
51 
46 
43 
39 
33 
28 
dB/100m 
 
 
 
ACR 
 
 
 
Frequency 
10 
16 
20 
31.25 
62.5 
100 
MHz 
Spec. (Min.)
1) 
63 
52 
44 
39 
37 
31 
22 
14 
dB/100m 
Typical 
71 
61 
52 
48 
45 
40 
31 
24 
dB/100m 
 
 
 
Power sum ACR 
 
 
 
Frequency 
10 
16 
20 
31.25 
62.5 
100 
MHz 
Spec. (Min.)
1) 
60 
49 
41 
36 
34 
28 
19 
11 
dB/100m 
Typical 
69 
59 
50 
46 
43 
38 
29 
22 
dB/100m 
1)
: Specification values according to cable requirements of ISO/IEC 11801 category 5 enhanced 
2)
: Specification values according to cable requirements of ANSI/TIA/EIA-568-A-5 (enhanced) 
 
 
Standards 
Construction & Dimensions 
Electrical characteristics (at 20 ºC)
 
Application
 
Colour code 
  
Pair 1 
White-Blue/Blue 
Pair 2 
White-Orange/Orange 
Pair 3   White-Green/Green 
Pair 4 
White-Brown/Brown