Neutrik NE8MC6-MO etherCON NE8MC6-MO Data Sheet

Product codes
NE8MC6-MO
Page of 3
Slide the boot onto the cable.
Terminate RJ45 connector on the cable.
See following pages.
Press the locking latch of the RJ45 and place 
the two adapters onto the RJ45.
Put chuck onto the cable.
Slide RJ45 and chuck together into the housing.
Finish the assembly by turning the bushing 
onto the connector. Screw bushing fully up to 
the end.
onductors with an 
insulation.  O.D. 0.037” / 0.95 mm to 0.047” / 1.07 mm.
Jacket: 
O.D. 0.22” / 5.5 mm to 0.25” / 6.5 mm
Pay attention: Hold the brackets together.
Pay attention to the plug latch which has to be on 
the opposite side of the key.
Attention:  Pay attention to the guiding key.
Suitable cables:
AWG 22 to 28 soldid or stranded c
A
B
C
E
F
D
A
B
C
D
E
F
Key
Draft. Nr.: BDA 194 / 3102M1581      Update:
17.08.2011      
I
I
Data subject to change without prior notice.  2011  NEUTRIK  . ALL RIGHTS RESERVED.
®
©
www.neutrik.com
ASSEMBLY INSTRUCTION
NE8MC6 
etherCON Cable Connector CAT 6
|
  
R
R
NEUTRIK
  
AG
LI
T: +423
 
/
 
237
 
24
 
24
F: +423
 
/
 
232 53 93
NEUTRIK
  
USA Inc.
USA
T: +1
 
732
 
/
 
901
 
9488
F: +1
 
732
 
/
 
901 9608
(
)
NEUTRIK
  
UK  Ltd.
UK
T: +44
 
1983
 
/
 
811
 
441
F: +44
 
1983
 
/
 
811
 
439
NEUTRIK 
Vertriebs
 
GmbH
DE
 
/
 
NL
 
/
 
AT/DK
T: +49
 
8131
 
/
 
280
 
890
F: +49
 
8131
 
/
 
280
 
830
NEUTRIK France
FR
T: +33 1 / 4131 6750
F: +33 1 / 4131 0511
NEUTRIK Tokyo Ltd.
JP
T: +81 3 / 3663 4733
F: +81 3 / 3663 4796
NEUTRIK Hong Kong
 Ltd.
HK
T: +852 / 2687 6055
F: +852 / 2687 6052