Measurement ranges of the HF58B-r 
 
Instrument as delivered,
             
i.e. without preamplifier or attenuator            
switch "Adapter"("Pegelanpassung") to "0 dB"
 
Range 
Bar
 on LCD
 
Displayed value & unit 
  
  
  
Coarse 
      
0.01 - 19.99    mW/m² 
      
Medium 
  
  
  
00.1 - 199.9    µW/m² 
      
Fine 
  
  
  
0.01 - 19.99    µW/m² 
Simply read out, no correction factor 
  
     
 
 
With ext. Attenuator DG20, 
         
switch "Adapter" to "Attenuator -20 dB"
 
Range 
Bar
 on LCD
 
Displayed value & unit 
  
  
  
Coarse 
      
1 - 1999    mW/m² 
  
  
  
Medium 
      
0.01 - 19.99    mW/m² 
  
  
  
Fine 
      
.001 - 1.999    mW/m² 
Simply read out, no correction factor 
  
     
 
 
With ext. Preamplifier HV10, 
       
switch "Adaptor" to "Amplifier +10dB"
 
Range 
Bar
 on LCD
 
Displayed value & unit 
      
Coarse 
  
  
  
00.1 - 1999    µW/m² 
      
Medium 
  
  
  
0.01 - 19.99    µW/m² 
      
Fine 
  
  
  
.001 - 1.999    µW/m² 
Simply read out, no correction factor 
  
     
 
 
With ext. Preamplifier HV30, 
       
switch "Adapter"("Pegelanpassung") to "0 dB"
 
Range 
Bar
 on LCD
 
Displayed value & unit Actual 
unit
  
  
  
Coarse 
      
0.01 - 19.99    mW/m² 
µW/m² 
      
Medium 
  
  
  
00.1 - 199.9    µW/m² 
nW/m² 
      
Fine 
  
  
  
0.01 - 19.99    µW/m² 
nW/m² 
Same decimal point, but next smaller unit 
(Coarse = grob; Medium = mittel; Fine = fein) 
 
 
 
Why no column „dBm“? 
Most recommended limiting values for HF radiation are 
given in W/m² (sometimes also in V/m), which is why 
this instrument is displaying in power density, µW/m² 
resp. mW/m². A display in dBm as e.g. on a spectrum 
analyzer requires transformation by a complicated 
formula, which depends on frequency and specifics of 
the antenna used. A “reconversion” therefore does not 
make sense.  
Conversion Table           
( µW/m² to V/m )
 
µW/m²
mV/m  µW/m²
mV/m   µW/m²
mV/m  
0,01
1,94
1,0
19,4
100  194  
-
-
1,2
21,3
120  213  
-
-
1,4
23,0
140  230  
-
-
1,6
24,6
160  246  
-
-
1,8
26,0
180  261  
0,02
2,75
2,0
27,5
200  275  
-
-
2,5
30,7
250  307  
0,03
3,36
3,0
33,6
300  336  
-
-
3,5
36,3
350  363  
0,04
3,88
4,0
38,8
400  388  
0,05
4,34
5,0
43,4
500  434  
0,06
4,76
6,0
47,6
600  476  
0,07
5,14
7,0
51,4
700  514  
0,08
5,49
8,0
54,9
800  549  
0,09
5,82
9,0
58,2
900  582  
0,10
6,14
10,0
61,4
1000  614  
0,12
6,73
12,0
67,3
1200  673  
0,14
7,26
14,0
72,6
1400  726  
0,16
7,77
16,0
77,7
1600  777  
0,18
8,24
18,0
82,4
1800  824  
0,20
8,68
20,0
86,8
2000  868  
0,25
9,71
25,0
97,1
2500  971  
0,30
10,6
30,0
106
3000  1063  
0,35
11,5
35,0
115
3500  1149  
0,40
12,3
40,0
123
4000  1228  
0,50
13,7
50,0
137
5000  1373  
0,60
15,0
60,0
150
6000  1504  
0,70
16,2
70,0
162
7000  1624  
0,80
17,4
80,0
174
8000  1737  
0,90
18,4
90,0
184
9000  1842