Bk Precision BK-8500 Electronic Load 1 mA - 30 A 0.1 - 120 Vdc 0 - 300 W BK-8500 Data Sheet
Product codes
BK-8500
Byte
offset
Meaning
3
Partition scheme:
1 means 1 file of 1000 list steps
2 means 2 files of 500 list steps
4 means 4 files of 250 list steps
8 means 8 files of 120 list steps
2 means 2 files of 500 list steps
4 means 4 files of 250 list steps
8 means 8 files of 120 list steps
4-24
Reserved
0x4B Read the memory partitioning for storing list steps
Byte
offset
Meaning
3
Partition scheme:
1 means 1 file of 1000 list steps
2 means 2 files of 500 list steps
4 means 4 files of 250 list steps
8 means 8 files of 120 list steps
2 means 2 files of 500 list steps
4 means 4 files of 250 list steps
8 means 8 files of 120 list steps
4-24
Reserved
0x4C Save the list file
Byte
offset
Meaning
3
Storage location, a one byte integer from 1 to 8. This number must be
consistent with the number of list files allowed as set by the 0x4A command.
consistent with the number of list files allowed as set by the 0x4A command.
4-24
Reserved
0x4D Recall the list file
Byte
offset
Meaning
3
Storage location, a one byte integer from 1 to 8.
4-24
Reserved
0x4E Set minimum voltage in battery testing
Byte
offset
Meaning
3 to 6
4 byte little-endian integer specifying the minimum voltage in units of 1 mV
7-24
Reserved
0x4F Read minimum voltage in battery testing
Byte
offset
Meaning
3 to 6
4 byte little-endian integer specifying the minimum voltage in units of 1 mV
8500 DC Load Series
Version: September 2, 2009
Page 63 of 76