Gw Instek PEL-3111 Electronic Load PEL-3111 Data Sheet

Product codes
PEL-3111
Page of 174
 
 
PEL-3000 Programming Manual 
154
 
Enable Register 
The Enable register determines which status 
event(s) are enabled. Any status events (CC, 
CV, CR, CP, PRUN) that are enabled will set the 
corresponding bit in the CSummary Event 
Register.  
Questionable Status Registers  
 
Overview  
The Questionable Status Registers will show if 
any faults or errors have occurred.  
 
Questionable Status Register
8
3
4
2
2
1
1
0
OP
0
OC
OV
Bit weight
Bit Position
Condition
OP
0
OC
OV
PTR/NTR
OP
0
OC
OV
EVENT
OP
0
OC
OV
ENABLE
12-15
0
0
0
0
UV
0
OT
UV
0
OT
UV
0
OT
UV
0
OT
9
5-8
4
512
 
16
11
REV
REV
REV
REV
10
EXT
EXT
EXT
EXT
 
2048
1024
 
Events Bits 
OV: Over voltage condition occurred. 
OC: Over current condition occurred. 
OP: Over power condition occurred. 
OT: Over temperature condition occurred. 
UV: Under voltage condition occurred. 
EXT: External problem occurred. (Same a Para 
alarm event: UnReg, R.OCP, OHP condition 
occurred.) 
REV: A reverse voltage condition has occurred. 
Condition 
Register 
The condition register indicates the status of the 
protection systems. The condition register can 
only be changed by a change in the condition of 
the protection systems. Reading the condition 
register does not change the state of the 
condition register.