Gw Instek PEL-3111 Electronic Load PEL-3111 Data Sheet

Product codes
PEL-3111
Page of 174
 
 
COMMNAND OVERVIEW 
67 
Mode Subsystem Commands 
 
 
:MODE .................................................................................. 67 
[:MODE]:CRANge............................................................... 67 
[:MODE]:VRANge .............................................................. 68 
[:MODE]:RESPonse ............................................................ 68 
[:MODE]:DYNamic............................................................. 69 
 
:MODE 
Set
Query
 
 
Description 
Sets the operating mode. 
Syntax 
:MODE {CC | CR | CV | CP | CCCV | CRCV | CPCV } 
Query Syntax 
:MODE? 
Parameter/Return 
parameter  
CC 
CC mode 
CR 
CR mode 
 
CV 
CV mode 
 
CP 
CP mode 
 
CCCV 
CC + CV mode 
 
CRCV 
CR + CV mode 
 
CPCV 
CP + CV mode 
Example 
:MODE CC 
Sets the mode to CC mode. 
Query example 
:MODE? 
>CC 
Returns the operating mode (CC mode). 
[:MODE]:CRANge 
Set
Query
 
 
Description 
Configures the current range for all the applicable 
operating modes. 
Syntax 
[:MODE]:CRANge {HIGH | MIDDle | LOW } 
Query Syntax 
[:MODE]:CRANge?