Gw Instek PEL-3211 Electronic Load PEL-3211 Data Sheet

Product codes
PEL-3211
Page of 174
 
 
COMMNAND OVERVIEW 
155 
PTR/NTR Filters 
The PTR/NTR (Positive/Negative transition) 
register determines the type of transition 
conditions that will trigger an event. Only the 
CSummary Status Register, Questionable Status 
Register and Operation Status Register can be 
transition programmed. 
Event Register 
The Event Register indicates if an event has 
been triggered according to the transition 
settings from the PTR/NTR Register. 
Enable Register 
The Enable register determines which status 
event(s) are enabled. Any status events (OV, 
OC, OP, OT, UV, EXT or REV) that are enabled 
will set the corresponding bit in the  
Questionable Event Register.  
Operation Status Registers  
 
Overview  
The Operation Status Registers will show the 
operating state of electronic load (waiting for a 
trigger or in calibration mode). 
 
Operation Status Registers
32
5
 
1-4
1
0
WTG
0
CAL
Bit weight
Bit Position
Condition
WTG
0
CAL
PTR/NTR
WTG
0
CAL
EVENT
WTG
0
CAL
ENABLE
 
Events Bits 
CAL: Indicates that the unit is currently in 
calibration mode. 
WTG: Indicates that the unit is waiting for a 
trigger.