Hengstler Tico-MFH-12-30VDC-TG-2-USB CR0773502 Data Sheet

Product codes
CR0773502
Page of 7
Data sheet tico 772/773/774 
19/07/2012
All rights reserved
Page 2 of 7 
Multifunctional counter  tico 772/773/774
tico 772/773/774
Amplitude threshold  <2 V and >8 V or <1 V and >4 V at TTL level, 
 
Amplitude max. 40 VDC
Active edge 
Programmable  positive for PNP input, 
 
 
  negative for NPN input
Input resistance 
Approx. 10 kOhm
Count
 
frequency 
Max. 60 kHz; 30 Hz attenuated 
 
max. 20 kHz; 30 Hz attenuated in TTL operation 
 
Application input max. 6 kHz/30Hz attenuated 
 
To prevent the maximum input frequency of 60 kHz being 
  
exceeded, the following maximum input frequencies apply: 
 
Phase discriminator, single evaluation: A and B, each 30 kHz (20 kHz) TTL 
 
Phase discriminator, double evaluation: A and B, each 30 kHz (20 kHz) TTL 
 
Phase discriminator, quad evaluation: A and B, each 15 kHz (15 kHz) TTL 
 
Single-channel metering & directional input: input A 60 kHz (20 kHz) TTL 
 
Differential metering, totalizing: input A + B 60 kHz (20 kHz) TTL 
 
If the application input is also used as a metering input: 
 
Single-channel metering & directional input: input A + app. input 
 
60 kHz (20 kHz) TTL 
 
Differential metering, totalizing: input A + B + app. input 
 
60 kHz (20 kHz) TTL 
 
->refer to graph on Page 5 
 
Pulse wave shape 
Any (at max. frequency, square 1:1)
Pulse duration min. 
17 ms (30 Hz); 8 µs (60 kHz)
Prescaler 0.0001-99.9999
Reset 
Manual reset via keyboard, external static or dynamic reset,   
 
min. pulse length 5 ms, automatic reset after reaching Preset 2. 
 
No pulse losses at max. counter frequency due to automatic reset  
 
function. Via programmable application input and programmable 
 
power-on reset
Set function 
Setting to Preset 0 (independent of reset)
Display and 
-999,999 to +999,999 
preset range
Alarm signal 
Display flashes when preset 0, 1 or 2 is active
Signal times 
0.01 s to 599.99 s or bistable programming; tolerance ± 10 ms; 
 
active on or off
Relay
 
Change-over contact max.: 250 VAC/30 VDC/5 A 
(Presets 1 and 2)
 
Change-over contact min.: 5 VAC/5  VDC/10 mA;  
 
delay <10 ms
Transistor output 
PNP output 
12-30 VDC, max. 50 mA for DC supply 
(Presets 1 + 2) 
 
 
12-24 VDC, max. 30 mA for AC supply 
 
 
 
24 VDC, max. 50 mA for AC supply with switch- 
 
 
 
mode power supply 
Application output 
PNP output 
12-30 VDC, max. 20 mA for DC supply 
 
 
 
12-24 VDC, max. 20 mA for AC supply 
 
 
 
24 VDC, max. 20 mA for AC supply with switch- 
 
 
 
mode power supply
AC transformer only  Combined current load of outputs (sensor 12-24 VDC, Out1, Out2,  
 
app. output) must not exceed 65 mA.