Kern Counting scales CXB 15K1 Weight range 15 kg Readability 1 g mains-powered, rechargeable Silver CXB 15K1 User Manual

Product codes
CXB 15K1
Page of 54
 
CXB/CXP-BA-e-1016 
26 
9  Parts counting 
With parts counting you can either count parts into a container or remove parts from 
a container. To count a greater number of parts the average weight per part has to 
be determined with a small quantity (reference quantity). The larger the reference 
quantity, the higher the counting exactness. High reference must be selected for 
small parts or parts with considerably different sizes. 
9.1  Determination of the reference weight by weighing 
 
Set balance to zero and tare, as required. 
0
W
a
PRE-
TARE
 
0
 
0
M+
 
Place a known number of parts on the balance as reference weight 
118.3
a
PRE-
TARE
 
0
 
0
M+
 
If the "Weight" display is stable, enter the number of parts via number keys. 
118.3
a
PRE-
TARE
Weight 
100
Pieces 
1
M+
 
While the “number of pieces” display is flashing (3 sec) confirm by pressing the 
 
key. 
118.3
a
PRE-
TARE
 
SAnnP
 
------
M+
 
Dead stop control is carried out and the calculated reference weight appears on the 
display. 
118.3
a
PRE-
TARE
Weight 
1.1833
Reference weight 
100
M+
W
Pieces 
Now you can place the parts to be counted onto the weighing plate.  
All quantity parameters of your goods to be weighed are displayed: