Kern HCB 200K500 Crane Hanging Scales 200kg HCB 200K500 User Manual
Product codes
HCB 200K500
HCB-BA-defsi-0630
5
GB
Operating Instructions Hanging scale
1 Technical
data
KERN
20K10
20K50
50K20
50K100
Readability
10 g
50 g
20 g
100 g
Weighing
range
range
20 kg
20 kg
50 kg
50kg
KERN
99K50
100K200 200K100 200K500
Readability
50 g
200 g
100 g
500 g
Weighing
range
range
99 kg
100 kg
200 kg
200 kg
2 Basic
instructions
2.1 Proper
use
The balance you purchased is intended to determine the
weighing value of material to be weighed. It is intended to be
used as a “non-automatic“ balance, i.e. the material to be
weighed is manually and carefully suspended. As soon as a
stable weighing value is reached the weighing value can be
read.
weighing value of material to be weighed. It is intended to be
used as a “non-automatic“ balance, i.e. the material to be
weighed is manually and carefully suspended. As soon as a
stable weighing value is reached the weighing value can be
read.
2.2 Improper
Use
Do not use balance for dynamic weighings. In the event that
small quantities are removed or added to the material to be
weighed, incorrect weighing results can be displayed due to the
“stability compensation“ in the balance. (Example: Slowly drain-
ing fluids from a container suspended on the balance.) No
permanent load must remain on the balance. This may dam-
age the measuring system.
Impacts and overloading exceeding the stated maximum load
(max) of the balance, minus a possibly existing tare load, must
be strictly avoided. Balance may be damaged by this (danger
of breaking).
Caution:
small quantities are removed or added to the material to be
weighed, incorrect weighing results can be displayed due to the
“stability compensation“ in the balance. (Example: Slowly drain-
ing fluids from a container suspended on the balance.) No
permanent load must remain on the balance. This may dam-
age the measuring system.
Impacts and overloading exceeding the stated maximum load
(max) of the balance, minus a possibly existing tare load, must
be strictly avoided. Balance may be damaged by this (danger
of breaking).
Caution:
Ö Make sure that never persons or objects are under the
load which could be injuried or damaged!
Ö The balance is not suitable for weighing persons!
Ö The balance does not correspond to the law of medical
products (MPG).
Never operate balance in explosive environment. The serial
version is not explosion protected.
The structure of the balance may not be modified. This may
lead to incorrect weighing results, safety-related faults and
destruction of the balance.
The balance may only be used according to the described
conditions.
Other areas of use must be released by KERN in writing.
version is not explosion protected.
The structure of the balance may not be modified. This may
lead to incorrect weighing results, safety-related faults and
destruction of the balance.
The balance may only be used according to the described
conditions.
Other areas of use must be released by KERN in writing.
2.3 Warranty
Warranty claims shall be voided in case
Warranty claims shall be voided in case
•
Our conditions in the operation manual are ignored
•
The appliance is used outside the described uses
•
The appliance is modified or opened,
mechanical damage and damage caused by media, liquids
mechanical damage and damage caused by media, liquids
•
Natural wear and tear
•
The appliance is improperly set up or incorrectly electri-
cally connected
cally connected
•
The measuring system is overloaded
2.4
Monitoring of Test Resources
In the framework of quality assurance the measuring-related
properties of the balance and, if applicable, the testing weight,
must be checked regularly. The responsible user must define a
suitable interval as well as type and scope of this test. Informa-
tion is available on KERN’s home page (www.kern-sohn.com)
with regard to the monitoring of balance test substances and
the test weights required for this. In KERN’s accredited DKD
calibration laboratory test weights and balances may be cali-
brated (return to the national standard) fast and at moderate
cost.
properties of the balance and, if applicable, the testing weight,
must be checked regularly. The responsible user must define a
suitable interval as well as type and scope of this test. Informa-
tion is available on KERN’s home page (www.kern-sohn.com)
with regard to the monitoring of balance test substances and
the test weights required for this. In KERN’s accredited DKD
calibration laboratory test weights and balances may be cali-
brated (return to the national standard) fast and at moderate
cost.
3
Basic Safety Precautions
Ö Do not use the suspended balance for conveying loads
Ö Never exceed the maximum permitted load (!!Danger of
Ö Never exceed the maximum permitted load (!!Danger of
breaking!!).
Ö Always ensure that there are no persons, animals or
objects that might be damaged underneath the load.
Ö Avoid any kind of shock, torsion and oscillating (e.g.
caused by inclined suspending)
No No
OK
Do not use
under pressure
under pressure
Do not twist
Only apply under
tensile force
tensile force
3.1
Pay attention to the instructions in the Operation Man-
ual
ual
Carefully read this operation manual before commissioning,
even if you are already familiar with KERN balances.
even if you are already familiar with KERN balances.
3.2 Personnel
training
The appliance may only be operated and maintained by trained
personnel.
personnel.