Kern Counting scales Weight range 30 kg Readability 0.5 g mains-powered, rechargeable CPB 30K0.5N User Manual

Product codes
CPB 30K0.5N
Page of 49
CPB-N / CPB-DM-BA-e-1323 
25 
Overview for service parameter: 
 
*
 = Factory settings 
 = The menu item is blocked; to modify press the justification button. 
 
Menu block 
Main menu 
Menu item  
Submenu 
Available settings / explanation 
F1  CAL
 
 
Adjustment 
 
F2  rES
 
 
6000d * 
Resolution 
duAL 
Always use this setting 
30000 d 
 
3000 d 
 
 
F3  Cnt
 
 
A/D - value 
 
F4  AU 
Add-up mode 
and data output
 
AU on* 
Automatic 
summation 
mode  
b9600*, b600, 
b1200, b2400, 
b4800 
LP 50 
EnG 
CHi 
Not documented 
tP 
Standard printer setting 
P ASt 
b9600*, b600, 
b1200, b2400, 
b4800 
EnG 
CHi 
Remote control 
instructions 
P Cont 
b9600*, b600, 
b1200, b2400, 
b4800 
Sd0 on 
Send zero on
 
Continuous data 
output 
Sd0 off 
Send zero off 
AU off 
Manual 
summation 
mode 
 
b9600*, b600, 
b1200, b2400, 
b4800 
LP 50 
EnG 
CHi 
Not documented 
tP 
Standard printer setting 
 
F5  tAr 
 
Pre-Tare 
Pt oFF
*
 
Pretaring value off: Always use this setting 
Pt on 
Pretaring value on 
 
F6  Pin 
 
Password 
Pin 1* 
Enter the new password 
Pin 2 
Confirm the new password 
 
F7  SPd 
 
Display speed 
SPd 7.5* 
not documented 
SPd 15 
SPd 30 
SPd 60 
 
F8  oFF 
Auto Off 
oF 0* 
Automatic shutdown off 
oF 3 
Automatic shutdown after 3 min 
oF 5 
Automatic shutdown after 5 min 
oF 15 
Automatic shutdown after 15 min 
oF 30 
Automatic shutdown after 30 min