Analog Devices ADP1752 Evaluation Board ADP1752-1.5-EVALZ ADP1752-1.5-EVALZ Data Sheet

Product codes
ADP1752-1.5-EVALZ
Page of 12
EVAL-ADP1752/ADP1753 
 
 
Rev. 0 | Page 4 of 12 
OUTPUT VOLTAGE MEASUREMENT 
Figure 3 shows how the evaluation board can be connected to a 
voltage source and a voltmeter for basic output voltage accuracy 
measurements. A resistor can be used as the load for the regulator.  
Ensure that the resistor has a power rating adequate to handle 
the power expected to be dissipated across it. An electronic load 
can be used as an alternative. In addition, ensure that the voltage 
source can supply enough current for the expected load levels. 
Follow these steps to connect to a voltage source and voltmeter: 
1.  Connect the negative terminal (−) of the voltage source to 
one of the GND pads on the evaluation board.  
2.  Connect the positive terminal (+) of the voltage source to 
the VIN pad of the evaluation board.  
3.  Connect a load between the VOUT pad and one of the 
GND pads.  
4.  Connect the negative terminal (−) of the voltmeter to one 
of the GND pads. 
5.  Connect the positive terminal (+) of the voltmeter to the 
VOUT pad.  
The voltage source can now be turned on. If J1 is inserted 
(connecting EN to VIN for automatic startup), the regulator 
powers up. 
If the load current is large, connect the voltmeter as close as 
possible to the output capacitor to reduce the effects of IR drops. 
 
VOLTMETER
+
VOLTAGE SOURCE
1.99711
LOAD
+
07
73
9-
0
03
 
Figure 3. Output Voltage Measurement Setup