Atmel Xplained Pro Evaluation Kit ATSAM4E-XPRO ATSAM4E-XPRO Data Sheet

Product codes
ATSAM4E-XPRO
Page of 1506
347
SAM4E [DATASHEET]
Atmel-11157D-ATARM-SAM4E16-SAM4E8-Datasheet_12-Jun-14
16.6.7 RTC Status Register
Name: RTC_SR
Address:
0x400E1878
Access: Read-only 
ACKUPD: Acknowledge for Update
ALARM: Alarm Flag
SEC: Second Event
TIMEV: Time Event
Note: The time event is selected in the TIMEVSEL field in the Control Register (RTC_CR) and can be any one of the following events: 
minute change, hour change, noon, midnight (day change).
CALEV: Calendar Event
Note: The calendar event is selected in the CALEVSEL field in the Control Register (RTC_CR) and can be any one of the following 
events: week change, month change and year change.
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
TDERR
CALEV
TIMEV
SEC
ALARM
ACKUPD
Value
Name
Description
0
FREERUN
Time and calendar registers cannot be updated.
1
UPDATE
Time and calendar registers can be updated.
Value
Name
Description
0
NO_ALARMEVENT
No alarm matching condition occurred.
1
ALARMEVENT
An alarm matching condition has occurred.
Value
Name
Description
0
NO_SECEVENT
No second event has occurred since the last clear.
1
SECEVENT
At least one second event has occurred since the last clear.
Value
Name
Description
0
NO_TIMEVENT
No time event has occurred since the last clear.
1
TIMEVENT
At least one time event has occurred since the last clear.
Value
Name
Description
0
NO_CALEVENT
No calendar event has occurred since the last clear.
1
CALEVENT
At least one calendar event has occurred since the last clear.