• TRACKTIM: Tracking Time
Tracking Time = (TRACKTIM + 1) * ADCClock periods.
• USEQ: Use Sequence Enable
5
SUT80
80 periods of ADCClock
6
SUT96
96 periods of ADCClock
7
SUT112
112 periods of ADCClock
8
SUT512
512 periods of ADCClock
9
SUT576
576 periods of ADCClock
10
SUT640
640 periods of ADCClock
11
SUT704
704 periods of ADCClock
12
SUT768
768 periods of ADCClock
13
SUT832
832 periods of ADCClock
14
SUT896
896 periods of ADCClock
15
SUT960
960 periods of ADCClock
Value Name
Description
0
NUM_ORDER
Normal Mode: The controller converts channels in a simple numeric order depending only on the 
channel index.
1
REG_ORDER
User Sequence Mode: The sequence respects what is defined in ADC_SEQR1 and ADC_SEQR2 
registers and can be used to convert several times the same channel.
Value
Name
Description